Before you start...

Your safety and the safety of others are very important.

We have provided many important safety messagesin this manuaIand on your appliance. Always readand obey all safety messages.

This is the safety abrt symb0i.

This symb0t abrts you to potential hazards that can kiii or hurt you and others.

Ati safety messageswiii f0ii0w the safety alert symbol and either the word "DANGER"or "WARNING". These words mean:

Cabinet opening dimensions

25" (63.5 cm) countertop depth (with or without backsplash)

and 24" (61 cm) base cabinet depth, 36" (91.4 cm) countertop height

Freestanding

 

max.

/

 

 

 

Range

upper cabinet depth

_'_l

For minimum

18" (45.7 cm)

upper cabinet to

 

 

 

 

30"

(76.2

cm)

cabinet clearance to

 

countertop

 

 

 

 

 

 

opening width

30" (76.2 cm)

_ ,_ opening width

3"

(7.6 cr_

(22.9 cm)

4" (10.2 cm) rain. clearance

You can be kilbd or sed0usly injured if you don't follow instructions.

AII safety messageswilI teli you what the p0tentiai hazard is, teli you how to reduce the chance of injury, and teii you what can happenif the instructions are not followed.

WARNING: _f the information in this

manual is not folmowed exactly, a fire or explosion may resuJt causing

property damage, personal injury or death.

- Do not store or use gasoline or

from both sides of range to side wall or other

combustible material.

Gas tine opening can be located within this

area.

6"

!(15.2 cm)

.10" Outlet shoutd be

cm) located within the 18" x 10" (45.7 cm x 25.4 cm) shaded area.

 

I

2-1/2" (6.4 cm)

I

\floorgas,he

\

opening if

directly

_. I _- /

below

regulator

 

 

7/8"

(2.2

cm) rain.

 

 

required

between

 

 

 

opening

 

 

and

door

or hinge

 

 

opening.

 

 

other flammabme vapors and liquids in the vicinity of this or any other appliance.

-WHAT TO DO iF YOU SMELL GAS

o Do not try to _ight any appliance.

o Do not touch any e_ectrica_ switch

o Do not use any phone in your building.

o Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

o if you cannot reach your gas supplier, call the fire department.

-installation and service must be performed by a qualified installer, service agency or the gas supplier.

In the State of Massachusetts, the following installation instructions apply:

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or

gasfitter qualified or licensed by the State of Massachusetts.

If using a ball vaK,e, it shaft be a T-handb type.

A flexible gas connector, when used, must not exceed 3 feet.

Slide-in

 

 

 

 

_

 

 

 

 

_j_._

4" (10.2 cm) rain.

 

 

clearance

from

both

sides /

I

of range

to side

wali

or __

",.,_.,_/"

other combustible matehal.

" m,,"

 

 

 

 

¢

 

 

 

(22.9

cm)

(7.6 cm)

Gas line opening should be tocated within this

shaded area.

floor gas fine opening directly below

max. upper

 

 

 

f

 

 

 

 

For minimum

18" (45.7 cm)

cabinet

 

depth

_

upper cabinet

 

clearance

to

 

to countertop

30" (76.2

cm) cabinet

cooktop,

see

 

 

 

 

 

 

 

 

 

 

***NOTE

 

opening

width

 

 

 

 

30" (76.2

cm)

 

 

 

 

opening

width

 

 

 

 

IMPORTANT:

Rear vent must be instalbd on all slide-in

models for proper

ventilation. See Step 7, Panel D.

Outlet should be located within the 18" x 10"

(61 cm) (45.7 x 25.4 cm) shaded area.

7/8" (2.2 cm) min. required between pening and door or hinge

opening.

Countertop opening dimensions that are shown

must be used. Given dimensions provide required clearances.

When installing a range under existing cabinets and the installation does not meet the minimum

cabinet clearances, install a range hood above the range to avoid burn hazards.

Read electrical and carpentry instructions.

Proper installation is your responsibility. A qualified technician must install this range. Make sure you have everything necessary for correct installation. it is the customer's responsibility to make sure that the countertop has been properly prepared and that the installation clearances specified on the model/serial rating plate are met. The model/serial rating plate is located on the oven frame behind the oven drawer.

Check location where range wifl be installed. The range should be located for convenient use in the kitchen. Recessed installations must provide complete enclosure of the sides and rear of range.

Aft openings in the wall or floor where range is to be installed must be sealed.

IMPORTANT: Some cabinet and building materials are not designed to withstand the heat produced by the oven for baking and self-cleaning. Check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage.

It is the customer's responsibility:

To contact a qualified electrical instafler.

To assure that the ebctrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 -- latest edition*, or CSA Standard C22.1, Canadian Electrical Code, Part 1 -- latest edition**, and all local codes and ordinances.

NOTE: This appliance is manufactured for use with Natural Gas. Conversion to LR Gas can be made

using the kit included in your literature package.

NOTE: The metal chassis of the range must be grounded in order for the control panel to work. If the metal chassis of the range is not grounded, no keypads will operate. Check with a qualified electrician if you are not sure the range is grounded.

IMPORTANT: Observe all governing codes and ordinances.

Grounded ebctdcal outlet is required. See "Electrical requirements," Panel C.

Cabinet opening dimensions that are shown must be used.

Do not pinch the power supply cord between the range and the wall.

Do not seal range to side cabinets.

Copies of the standards listed may be obtained from: *National Fire Protection Association

One Batterymarch Park Quincy, Massachusetts 02269

**CSA International

8501 East Pleasant'Valley Road Cleveland, Ohio 44131-5575

***NOTE 24" (6I cm) rain. when bottom of wood or metal cabinet is protected by not less than 1/4"

(6.4 mm) flame retardant miltboard covered with not tess than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 ram) copper.

30" (76.2 cm) rain. clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet.

Panel A