ran es:
countertop preparation
30 _
(76.2 cm)
opening,1/2" width
p"
(78.4 cm) Formed or tiled countertop
. /trimmed 1/2" (1.3 cm)back at front corners of
countertop opening.
(63.5 cm)
Cooktop sides of range fit over edges of countertop opening.
for
ation:
Assemble the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
level
Phillips scewdriver
adjustable wrench pliers
hammer
The cooktop sides of the siidedn range fit over the cutout edge of your countertop.
if you have a square finish (flat) countertop and the opening width is 30" (76.2 cm), no countertop preparation is required.
Formed
Tile countertops may need trim cut back 1/2" (1.3 cm) from each front corner andlor rounded edge flattened.
if countertop opening width is greater than
30" (76.2 cm), adjust the 1/2" (1.3 cm) dimension.
Countertop must be level. Place level on countertop, first side to side; then front to back. if countertop is not level, range will not be level
Oven must be level for satisfactory baking conditions.
measureing tape or ruler hand or electric drill
wood floor: 1/8" (0.3 cm) drift bit
concrete/ceramic floor: 3/16" (0.48 cm)
•LR gas conversion requires: pin pick up (claw attachment)
•5/16" nut driver
arts sup for
uct dimensions
Freestanding Range
30" (76.2 cm) range width
(91.8 cm) cooktop height
(112.7 cm)
(70.5 cm)
depth with
handle
Slide-in Range
]
30" | (76.2 | cm) _1 | |
| rear | vent | width |
n:
•burner grates and caps
•vent cap
•LR conversion orifice spud kit:
1- 0.95 mm (0.0374") cooktop (blue)
2 - 0.67 mm (0.0264") cooktop (black)
1- 1.05 mm (0.0413") cooktop (green)
1
plastic anchors
(#10 x
(Bracket must be securely mounted to
Mobile home installation
The installation of this range must conform to the Manufactured Home Construction and Safety
Standards, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD, Part 280); or when such standard is not applicable, the Standard for Manufactured Homes installations (Manufactured Home Sites, Communities and Setups), ANSI A225.1/NFPA 501A*, or with local codes.
(3.8 cm)
(2.54 cm) spacer
iMPORTANT:
Rear vent must be installed on aJJ
(91.8 cm) cooktop height
30 _
(76.2 cm) width
In Canada, the installation of this range must conform with the current standards
edition**, or with local codes.
When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.
Copies of the standards listed may be obtained from: * National Fire Protection Association
One Batterymarch Park Quincy, Massachusetts 02269
**CSA International
8501 East Pleasant'Valley Road Cleveland, Ohio
The floor
(70.5 cm) ...
depth
with handle
be installed. To install the
Panel B