Technical information
Electrical connection
GB
!Arrange the electrical power supply within the decorative flue dimensions.
!When making the electrical connections, check that the voltage values correspond to those indicated on the data plate inside the appliance itself.
!In case your appliance is not furnished with a non separating flexible cable and has no plug, or has not got any other device ensuring omnipolar disconnection from the electricity main, with a contact opening distance of at least 3 mm, such separating device ensuring disconnection from the main must be included in the fixed installation.
!If your unit features a power lead and plug, position this so the plug is accessible.
Technical data
| Model | HS110 | |
|
|
| |
| Dimensions | width 109.8 cm | |
|
| height 79 / 121 cm | |
|
| depth 49 cm | |
|
| Outlet pipe diameter 15 cm | |
|
|
|
|
| Gross weight | 17.9 Kg | |
|
|
| |
| Absorption | Total 215 W | |
|
| Motor 1x135 W | |
|
| Lamps 2x40 W | |
|
|
| |
| Flow rate | 358 m3/h | |
|
|
|
|
| Grease filters |
|
|
| Suction |
|
|
| surface area | 2673 cm2 |
4