Siemens 125-5033 On text, Override switch, Portable Operator’s Terminal, Sash sensor actuator

Page 32

Fume Hood Controller Owner's Manual

ON text

Text indicating the energized state of a digital point (for example, ON, OPEN, YES).

override switch

Button on room temperature sensor which can be pressed by an occupant to change the status of a room from night mode to day mode for a predetermined time.

PID

Proportional, Integral, Derivative.

Portable Operator’s Terminal

DOS capable laptop computer used along with the Controller Interface Software to monitor and communicate with Terminal Equipment Controllers.

RTS

Room Temperature Sensor.

sash sensor actuator

Device that rides along the sash sensor strip to vary the resistance reading to the Fume Hood Controller.

SI units

Systeme International d’Unites. The international metric system.

slave mode

Default application that comes up when power is first applied to a Terminal Equipment Controller.

slope

Factor which converts analog values (used by the controller) to a form which the user can understand (engineering units). Slope and intercept constants are determined by the type of field input/output represented by the physical or virtual point.

stand-alone control

The type of control offered by a controller that is providing independent DDC control to a space.

24

Siemens Building Technologies, Inc.

Image 32
Contents Two-State Constant Volume Fume Hood Controller 125-5033 Rev. AA, SeptemberPage Service Statement Page Table of Contents High and Low Exhaust Flow Control How To Use This Manual Manual OrganizationManual Conventions Convention ExampleManual Symbols Where To Send CommentsNotation Symbol Meaning Datamate SoftwareProduct Overview Related EquipmentElectronic Actuation Pneumatic ActuationOrdering Notes Application DescriptionPower Wiring Communication WiringHardware Inputs Hardware OutputsController LED Indicators Operator Display Panel ODPLED Type IndicationLaboratory Exhaust Air Terminal Operator Display PanelVenturi Air Valves Laboratory Exhaust Air TerminalHigh Speed Electronic Actuation Low Speed Electronic Actuation Pneumatic ActuationAnalog Output-Pneumatic AO-P Module Pneumatic ActuatorCables Differential Pressure TransmitterAirflow Sensor Fume Hood Controller 2-Position Constant Volume ApplicationsHigh and Low Exhaust Flow Control CalibrationControl Loops ElectronicAlarm Operation DO3 Output FunctionalityEmergency Purge Operation Emergency Purge FeatureAlarm Strategies Emergency Purge Strategies Fail-safe Operation Point Database Address Descriptor DescriptionFlow Coeff Flow P Gain Preventive Maintenance TroubleshootingBasic Service Information Safety Features Controller LEDsGlossary AlgorithmCentralized control Control loopOCC mode English unitsEquipment controller Field panelOverride switch Slave modeOn text Portable Operator’s TerminalUnocc mode Terminal Equipment ControllerIndex ApplicationIndex

125-5033 specifications

The Siemens 125-5033 is a highly regarded circuit breaker in the world of electrical engineering and power distribution. Known for its robust design and versatile applications, this device offers a host of features that make it suitable for both commercial and industrial use.

One of the main features of the Siemens 125-5033 is its compact size. This allows for easy integration into existing systems without occupying excessive space, making it an ideal choice for facilities with limited room for electrical infrastructure. Its ability to handle high current ratings, typically around 125 amps, ensures that it can support a variety of electrical loads, making it versatile across different applications.

The Siemens 125-5033 employs advanced technologies, such as thermal-magnetic trip mechanisms. This allows for reliable protection against overloads and short circuits. The thermal component of the trip mechanism is designed to react to sustained overcurrent conditions, while the magnetic component responds instantaneously to short circuits. This dual-functionality ensures that the circuit breaker can effectively protect both the conductors and the connected equipment.

In terms of safety, the Siemens 125-5033 comes with advanced arc suppression technologies that minimize the risk of arcing during the circuit interrupting process. This not only enhances the longevity of the breaker but also safeguards personnel working near electrical installations. Additionally, the device features a clear, accessible reset mechanism, making it user-friendly and easy to operate in case of an interruption.

Another notable characteristic of the Siemens 125-5033 is its built-in ground fault protection option. This capability provides an added layer of safety, ensuring that any ground faults are detected and addressed promptly. It is particularly useful in environments where moisture or dust can compromise electrical safety.

The Siemens 125-5033 also boasts compatibility with various monitoring and control systems, enabling seamless communication and integration into smart building management systems. This feature allows facility managers to monitor power usage, identify potential issues, and optimize energy consumption effectively.

Overall, the Siemens 125-5033 circuit breaker is a reliable, safe, and technically advanced choice for those looking to enhance their electrical systems. Its compact size, dual-trip mechanism, ground fault protection, and compatibility with modern technologies make it a valuable asset for any facility looking to improve its electrical safety and efficiency.