Siemens 125-1957 English units, Equipment controller, Field panel, Intercept, Ioopout, OFF text

Page 44

APOGEE Unit Vent Controller0 to 10V Output Owner’s Manual

DO

Digital Output. Physical output point that generates a two-state signal (that is, ON/OFF, OPEN/CLOSED, YES/NO, etc.).

English units

Foot-pound-second system of units for weights and measurements.

equipment controller

FLN device which provides additional point capacity to a field panel or provides individual room or mechanical equipment control. The Unit Vent Controller — 0 to 10V Output is an equipment controller.

field panel

Device containing a microprocessor for centralized control of system components and equipment controllers. A field panel samples and processes field data, initiates control actions, communicates with its operators, and generates reports, displays and warnings.

FLN

Field Level Network

intercept

Factor which converts analog values (used by the controller) to a form which the user can understand (engineering units). Slope and intercept constants are determined by the type of field input/output represented by the physical or virtual point.

FLN

Revised acronym for Floor Level Network. The term “Floor” is no longer used and has been replaced with “Field”.

Ioopout

Output of the control loop expressed as a percentage.

OFF text

Text indicating the de-energized state of a digital point (for example, OFF, CLOSED, NO).

34

Siemens Building Technologies, Inc.

Image 44
Contents Apogee Unit Vent Controller ⎯ 125-1957 Rev. CA, JulyPage Service Statement Page Table of Contents Point Database Troubleshooting Table of Contents How To Use This Manual Manual OrganizationManual Symbols Notation Symbol MeaningManual Conventions Datamate SoftwareWhere To Send Comments Getting HelpProduct Overview IntroductionOrdering Notes Standard ApplicationsDigital Hardware InputsAnalog Power Wiring Communication WiringHardware Outputs Analog 0 toRoom Temperature Sensor Controller LED IndicatorsTemperature Sensors Mixed Air/Discharge Air Temperature Sensor ActuatorsDamper Actuators Valve ActuatorsControl Temperature Setpoints Day/Night ModeApplications Basic OperationControl Loops Valve ConfigurationHeating and Cooling Switchover Morning Warm-up/Cool-down ON/OFF Coil Valve ControlElectric Heat Fan OperationBasic Operation Application 2281 Control Drawing Application 2281 Control Drawing Application 2281 Control Drawing Application 2283 Control Drawing Application 2283 Control Drawing Application 2283 Control Drawing Application 2284 Heating and DX Cooling, Ashrae Cycles I Application 2284 Control DrawingApplication 2284 Heating and DX Cooling, Ashrae Cycles I Application 2286 Heating and DX Cooling, Ashrae Cycle Application 2286 Control DrawingApplication 2286 Heating and DX Cooling, Ashrae Cycle Application 2287 Heating and Cooling Nesbitt Cycle W OverviewApplication 2287 Heating and Cooling Nesbitt Cycle W Application 2299 Slave Mode Point Database Descriptor Address Application DescriptionWall Switch RM Stpt MINRM Stpt MAX RM Stpt DialOvrd Time NGT OvrdAUX.NOAUX Free CLGAOV1SPAN AOV1STARTAOV2 Span AOV2 StartNGT CLG Mode EheatEhea T FANCLG Output OA Dmpr POSCLG P Gain CLG D GainSwitch Limit Switch TimeMA Loopout OA LoopoutSwitch Dband Error StatusNGT Dband Morn DbandOverview TroubleshootingBasic Service Information Ordering Replacement Parts Preventive MaintenanceSafety Features Controller LEDsGlossary AlgorithmCentralized control Control loopEnglish units Equipment controllerField panel InterceptOverride switch Slave modeOn text Sl unitsUnbundle Index BST LEDDDC FLNRTS TX LED

125-1957 specifications

Siemens 125-1957, a notable creation of the German engineering giant Siemens, is recognized for its innovative design and advanced technology in the realm of electrical engineering. This model is emblematic of the mid-20th century's commitment to optimizing electrical machinery for industrial applications, contributing to enhanced productivity and efficiency.

One of the main features of the Siemens 125-1957 is its robust construction, designed to withstand the demanding environments of industrial settings. The body of the machine is built from high-grade materials, ensuring durability and longevity. It is also designed to minimize vibration and noise during operation, thus enhancing the user experience.

Technologically, the Siemens 125-1957 incorporates advanced electric motor technology, which provides reliable performance across a variety of applications. The motor is designed for high efficiency, allowing it to operate effectively under load while consuming less energy. This efficiency is crucial in industrial applications where operational costs are significant. The motor is also equipped with thermally protected windings, which prevent overheating and extend the service life of the equipment.

The 125-1957 model is characterized by its adaptability in various operational settings. It is compatible with a range of automation systems, making it a versatile choice for factories and production lines. Its design allows for easy integration with existing equipment, minimizing downtime during installation.

Moreover, the Siemens 125-1957 boasts a user-friendly interface, making it accessible for operators with varying levels of expertise. It comes with comprehensive safety features, including circuit protection and emergency stops, ensuring that it meets the strict industrial safety standards.

In summary, the Siemens 125-1957 represents a blend of robust design, advanced motor technology, and user-oriented features. With its energy-efficient performance and adaptability, it stands out as a key asset in industrial electrical engineering, demonstrating Siemens' commitment to innovation and quality in the manufacturing sector. This model continues to be relevant, supporting various industries in their pursuit of efficiency and reliability.