INSTALLATION INSTRUCTIONS
Gas Category II2H3+ (GB,IE)
Model Numbers W810, BG05
These models are set to burn NATURAL GAS (G20) at 20mbar.
They can also be converted to burn BUTANE GAS (G30) at 28mbar or PROPANE GAS (G31) at 37mbar using the conversion kit included.
Technical Data
Gas Connection | Rp 1/4 (1/4” BSP female) |
Pressure test point | Burner injector |
Aeration adjustment | None |
Electrical Connection
Natural Gas
LPG
BURNER
Front Left
Rear Right
and Rear Left
Front Right
HEAT INPUT
3.0kW
2.0kW
1.15kW
INJECTOR
130
105
80
HEAT INPUT
3.0kW
2.0kW
1.15kW
INJECTOR
92
72
55