Hotpoint BG05 manual Installation Instructions, Gas Category II2H3+ GB,IE

Page 10

FP087-01 HP Gas Hob (BG05) 12/09/2001 4:59 pm Page 10

INSTALLATION INSTRUCTIONS

Gas Category II2H3+ (GB,IE)

Model Numbers W810, BG05

These models are set to burn NATURAL GAS (G20) at 20mbar.

They can also be converted to burn BUTANE GAS (G30) at 28mbar or PROPANE GAS (G31) at 37mbar using the conversion kit included.

Technical Data

Gas Connection

Rp 1/4 (1/4” BSP female)

Pressure test point

Burner injector

Aeration adjustment

None

Electrical Connection 230-240V ac. 50Hz Heat resistant PVC 85oC 0.75mm2 Flexible cord.

Natural Gas

LPG

BURNER

Front Left

Rear Right

and Rear Left

Front Right

HEAT INPUT

3.0kW

2.0kW

1.15kW

INJECTOR

130

105

80

HEAT INPUT

3.0kW

2.0kW

1.15kW

INJECTOR

92

72

55

10

Image 10
Contents Instructions for Installation USE Gas Hob BG05 Contents Introduction Safety Advice For Your SafetyAlways Never Using the GAS HOB Features Operation When Using the GAS HOBCare and Cleaning Something Wrong ? If the Ignition does not WorkInstallation electrical requirements Installation Instructions Gas Category II2H3+ GB,IELocation GAS Safety Installation & USE RegulationsProvision for Ventilation Siting the HOB InstallationFitting the HOB Fixing Clamp LPG Conversion Instructions for Models W810, BG05 Hotpoint Service Cover Key Contacts