Hotpoint GE641TX, GE640X, GE640TX specifications Positioned in or next to the tap pin

Page 4

• Setting the burners to minimum:

GB

1. Turn the tap to the low flame position.

 

 

2. Remove the knob and adjust

 

the adjustment screw, which is

 

positioned in or next to the tap pin,

 

until the flame is small but steady.

3.Having adjusted the flame to the required low setting, while the burner is alight, quickly change the position of the knob from minimum to maximum and vice versa several times, checking that the flame does not go out.

4.Some appliances have a safety device (thermocouple) fitted. If the device fails to work when the burners are set to the low flame setting, increase this low flame setting using the adjusting screw.

5.Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar substance.

!If the appliance is connected to liquid gas, the regulation screw must be fastened as tightly as possible.

!Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Stickers are available from any of our Service Centres.

!Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet pipe (in order to comply with current national regulations).

4

Image 4
Contents Operating Instructions HOBInstallation PositioningGas connection Positioned in or next to the tap pin Burner and nozzle specifications Liquid Gas Natural GasElectrical Connection Carried OUT by a Qualified ElectricianDescription of the appliance Overall viewPractical advice on using the burners Start-up and usePrecautions and tips General safetyDisposal Recycling & Disposal InformationMaintenance and care Switching the appliance offCleaning the appliance Gas tap maintenanceTroubleshooting Problem Possible causes/SolutionAfter Sales Service GuaranteeGB Page Page Xerox Business Services