Hotpoint GE640TX, GE640X, GE641TX Burner and nozzle specifications, Liquid Gas Natural Gas

Page 5

Burner and nozzle specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

GB

Table 1

 

 

 

Liquid Gas

 

 

 

Natural Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Diameter

Thermal

Thermal

By-pass

Nozzle

Flow*

 

Thermal

Nozzle

 

Flow*

 

 

(mm)

Power

Power

1/100

1/100

g/h

 

Power

1/100

 

g/h

 

 

 

kW

kW

(mm)

 

 

 

 

kW

 

 

 

 

 

 

(p.c.s.*)

(p.c.s.*)

 

 

 

 

 

(p.c.s.*)

 

 

 

 

 

 

Red.

Nom.

(mm)

(mm)

***

 

**

Nom.

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fast

100

0,70

3,00

41

86

218

 

214

3,00

116

 

286

 

(Large) (R)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reduced Fast

100

0,70

2,60

41

80

189

 

186

2,60

110 (Y)

 

248

 

(RR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi Fast

75

0,40

1,65

30

64

120

 

118

1,65

96

 

157

 

(Medium) (S)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

55

0,40

1,00

30

50

73

 

71

1,00

79

 

95

 

(Small) (A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Triple Crown

130

1,30

3,30

57

87

240

 

236

3,60

131

 

343

 

(TC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply

 

Nominal (mbar)

 

28-30

 

37

 

20

 

 

 

 

Minimum (mbar)

 

20

 

25

 

17

 

 

 

pressures

 

 

 

 

 

 

 

 

Maximum (mbar)

 

35

 

45

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*At 15°C and 1013 mbar-dry gas

**

Propane

P.C.S. = 50.37

MJ/kg.

***

Butane

P.C.S. = 49.47 MJ/kg.

 

Natural

P.C.S. = 37.78

MJ/m3

 

A

 

A

R

S

RR

TC

 

S

 

S

GE 640

 

GE 641 T

 

GE 640 TX

DATA PLATE

Electrical

220-240V ~ 50/60Hz

connections

 

This appliance conforms to the following European Economic Community directives:

-73/23/EEC dated 19/02/73 (Low Voltage) and subsequent amendments

-89/336/EEC dated 03/05/89 (Electromagnetic Compatibility) and subsequent amendments

-93/68/EEC dated 22/07/93 and

subsequent amendments.

- 90/336/EEC dated 29/06/90 (Gas) and subsequent amendments.

- 2002/96/EC

5

Image 5
Contents HOB Operating InstructionsPositioning InstallationGas connection Positioned in or next to the tap pin Liquid Gas Natural Gas Burner and nozzle specificationsCarried OUT by a Qualified Electrician Electrical ConnectionOverall view Description of the applianceStart-up and use Practical advice on using the burnersGeneral safety Precautions and tipsDisposal Recycling & Disposal InformationSwitching the appliance off Maintenance and careCleaning the appliance Gas tap maintenanceProblem Possible causes/Solution TroubleshootingAfter Sales Service GuaranteeGB Page Page Xerox Business Services