The following instructions are intended for the installer so that the installation and maintenance procedures may be followed in the most professional and expert manner possible. Important:

Disconnect the appliance from the electrical supply before performinganymaintenanceorrepair.

Positioning the Hob

Important: this unit may be installed and used only in permanently ventilated rooms in accordance with British Standard Codes Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S.6891 Current Editions.The following requirements must be observed:

a)The room must be fitted with a ventilation system which vents smoke and gases from combustion to the outside.This must be done by means of a hood or electric ventilator that turns on automatically each time the hob is operated.

In a chimney stack or branched flue.

Directly to the Outside

(exclusively for cooking appliances)

b)Theroommusthaveanairflowtoallowforpropercombustion. Thismustbe2m3³/hperkWofinstalledpower.Theairflowcan be created using an enclosed vent with an inner cross section of at least 100 cm² which must not be able to be blocked. I the appliance does not have a flame failure device, the vent must haveaninternalcrosssectionof200cm3³(Fig. A). Alternatively the room in which the hob is situated can be vented indirectly through ventilation ducts as specified above, as long as the adjacent room is not a shared area, a bedroom or present any

riskoffire(Fig. B).

 

 

Detail A

 

 

 

 

Adjacent

Room to be

 

 

 

 

 

 

 

 

 

 

 

 

Room

Vented

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

Examples of ventilation holes

Enlarging the ventilation slot

for comburant air.

between window and floor.

Fig.A

Fig.B

c)Intensiveandprolongeduseoftheappliancemaynecessitate supplemental ventilation, e.g. opening a window or increasing the power of the air intake system (if present).

d)Liquidifiedpetroleumgasesareheavierthanairand,asaresult, settle downwards. Rooms in which LPG tanks are installed mustbefittedwithventilationopeningstotheoutsideinorderto allow the gas to escape in the event of a leak. Therefore, LPG tanks, whether empty or partially full, must not be installed or storedinroomsorspacesbelowgroundlevel(cellars,ect.).Itis also a good idea to keep only the tank currently being used in theroom,makingsurethatitisnotnearsourcesofheat(ovens, fireplaces,stoves,etc.)thatcouldraisetheinternaltemperature of the tank above 50°C.

Installation of Built-in Hobs

The gas hob is equipped with type X degree protection against overheating. Therefore, the appliance can be installed next to cabinets,providedtheheightofthecabinetdoesnotexceedthatof the hob. For proper installation of the hob, the following guidlines must be followed:

a)If the cabinet(s) located next to the hob are higher than the hob itself, the cabinet(s) must be installed at least 110 mm from the hob edge.

b)Hoods must be installed in accordance with the instructions contained in the installation manual for the hoods themselves, and no less than 650 mm from the hob.

c)In the case of the 600 mm cooker hoods, besides following the recommendations in point b), the cabinets should be positioned next to the hood at a height of at least 540 mm from the top since this will make it possible to install the lid and move it correctly.The cabinet should always be installed at a height from the top which allows easy use of pots and pans on the cooker.

d)Shouldthehobbeinstalleddirectlyunderacupboard,thelatter shouldbeatleast700mm(millimetres)fromthetop,asshown inFigureC.

Fig. C

 

 

 

 

 

 

 

 

HOOD

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. 600 mm.

 

min. 650 mm. with hood min. 700 mm. without hood

 

 

 

 

 

Min. 420 mm.

 

 

Min. 420 mm.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

e)The dimensions of the cutout for the appliance must be those indicatedinthefigureD.Clampsareprovidedtofastenthehob tocountersmeasuringfrom20to40mminthickness.Tofasten the hob securely, it is recommended that all the clamps be used.

Fig. D

 

 

 

555 mm.

 

 

 

 

 

 

 

 

 

.

 

 

 

55

mm

 

 

mm

.

 

 

 

 

 

 

 

475

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Image 8
Contents Instructions for Installation and Use Contents Introduction For Your Safety AlwaysModel GD74, GD74 CH How To Use Your HobKnow your Hob Practical Advice Care and CleaningPractical Advise on Using the Burners Greasing the Gas ValvesTroubleshooting If the cookware is not stableInstallation Installation of Built-in HobsFastening Clamps Assembly Diagram =30mm top =40mm top Front=20mm topBack Gas Connection for the HobMinimumRegulation Adapting the Hob for Different Types of GasRegulation of Air Supply to the Burner Live Electrical ConnectionEarth Characteristic of the burners and nozzles Liquid Gas Natural GasPage Repair Service and Information Help Desk Guarantee Key Contacts

GD74 CH, GD74, GF740, GE740TCX, GD64 specifications

The Hotpoint GD64, GE740TCX, GF740, GD74, and GD74 CH are a series of kitchen appliances designed with modern cooking needs in mind. Each model boasts unique features, ensuring homeowners can find the perfect match for their culinary endeavors.

The Hotpoint GD64 is notable for its stylish aesthetics coupled with practical functionality. This model features a double oven configuration, with one being a fan-assisted oven that ensures even heat distribution, ideal for baking and roasting. The modern energy efficiency rating also allows for reduced energy consumption without compromising performance. With a programmable timer and multiple cooking modes, it simplifies meal preparation while providing a contemporary touch to any kitchen.

Moving on to the GE740TCX, this range offers a robust cooking experience with its multifunctionality. It includes a gas burner option for those who appreciate the control and instant heat of gas cooking. Additionally, the ceramic hob surface provides a smooth and easy-to-clean area for cooking, while the integrated safety features like flame failure devices offer peace of mind. Its spacious oven allows for large meal preparations, making it an outstanding choice for family gatherings.

The GF740 model stands out with its innovative features embedded in a sleek design. This model is equipped with advanced cooking technology, including a pyrolytic self-cleaning function that saves significant time and effort. This self-cleaning feature utilizes high temperatures to carbonize food residues, allowing users to simply wipe away the ash left behind. Energy efficiency remains a priority with this model, ensuring that users can cook sustainably.

The GD74 and GD74 CH models are particularly appealing for their user-centric design and versatility. Both models embrace a variety of cooking functions, such as grilling and baking, all incorporated into a user-friendly interface. The GD74 CH variant additionally emphasizes health-conscious cooking with its grill features that enable delicious results while reducing fat content.

Across the spectrum, all models feature durable materials, modern aesthetics, and thoughtful ergonomics, ensuring they not only perform exceptionally but also enhance the visual appeal of contemporary kitchens. Whether you are a novice cook or a culinary enthusiast, the Hotpoint series provides robust solutions tailored to diverse cooking styles and preferences.