Installation

The cooker is of type X with regard to protection against overheating of surrounding surfaces as defined in BS EN60335-2-6: 1991 it can be close fitted below hotplate level. This requires a minimum distance of 503mm between cupboard units of hotplate height.

When installing next to a tall cupboard, partition or wall, for a minimum distance of 400mm above hotplate level, allow a side clearance of at least 65mm.

The diagram below illustrates the minimum clearance between the cooker and adjacent walls, cupboards etc.

The wall behind the cooker 150mm below the hotplate and 450mm above, and the width of the cooker, must be a non-combustible material such as ceramic wall tiles.

If the cooker is to be fitted close to a corner on the left hand side, ensure that there is a clearance of at least 50mm to allow the main oven door to open fully for when removing oven shelves.

The height of the cooker can be adjusted by means of adjustable feet in the plinth (900mm - 915mm). Adjust the feet by tilting the cooker from the side. Then install the product into position.

400 mm Min

mmMin

 

750

65 mm Min

 

503 mm Min

Cooker Hoods If a cooker hood is to be installed, refer to the cooker hood manufacturers’ instructions regarding fixing height.

23

Image 23
Contents Hotpoint EG21 Cooker Instruction Recipe Book Contents Introduction Always For Your SafetyFor Your Safety Never Features Control Panel When the appliance is not in useHotplate To Use the Hob Safety Requirements for Deep Fat FryingHow to Deal with a Fat Fire Gas Mark Conventional Fan Oven Temperature Conversion ScaleGrill Compartment as a ‘Hotcupboard’ Using the GrillTo Use the Grill Grill Pan Handle Using the Fan Oven To prepare meat and poultry for roasting in your fan oven Oven Cookery NotesOven Temperature Charts Meat Time in mins Food PreBeef Stew and Dumplings Recipes For Fan OvenBatters Christmas Cake Cooker Finish Cleaning Method Care and CleaningOven Liners sides How ‘Stayclean’Works Something Wrong with your Cooker? Problem CheckModel Number EG21 InstallationGeneral Technical Data DimensionMmMin 750 Moving the Cooker Splash Panel Kit Wall Mounted 250 530 Connecting To The Gas SupplyUnpacking the Cooker Stability Chain 300Installation Checks OperationalHotpoint Service Cover Page Page Page Key Contacts