Master Port | Switch |
|
Control | Ports | |
TD |
| TD Port A |
|
| TD Port B |
UART |
| TD Port C |
Microcontroller |
| TD Port D |
|
| |
|
| TD Port E |
|
| TD Port F |
|
| TD Port G |
Port Combiner |
| TD Port H |
Control Lines |
| CTS Port A |
|
| |
|
| CTS Port H |
Figure 1. Simplified Functional Diagram
NOTE: This diagram illustrates only the transmit data (TD) signal.
Checklist
The following equipment should be in the shipping carton:
1.Smart Switch
2.Instruction Manual
3.(2) 3 1/2" disks
If any of the items above are damaged or missing contact the shipper immediately.
Serial Data Configuration
In order for the host device, which is connected to the Master Port of the Smart Switch, to select a port, the Smart Switch must be set to match the host's communication format. This is accomplished by setting an eight position DIP switch labeled "SW1" located inside the Smart Switch. Refer to Figure 2. Switch positions 1 through 4 select the baud rate. Switch position 5 selects 7 or 8 data bits. Refer to Table 1. The remaining switch positions will be discussed later. Always power down the Smart Switch before changing switch settings.
Documentation Number 232D4SS84502 Manual | 3 |
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph