Table 1. Communication & Configuration Switch
|
| DIP Switch 1 |
|
|
| ||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | Setting | |
0 | 0 | 0 |
| 0 | X | X | X | X | 300 Baud |
1 | 0 | 0 |
| 0 | X | X | X | X | 600 Baud |
0 | 1 | 0 |
| 0 | X | X | X | X | 1200 Baud |
1 | 1 | 0 |
| 0 | X | X | X | X | 2400 Baud |
0 | 0 | 1 |
| 0 | X | X | X | X | 4800 Baud |
1 | 0 | 1 |
| 0 | X | X | X | X | 9600 Baud * |
0 | 1 | 1 |
| 0 | X | X | X | X | 19.2K Baud |
1 | 1 | 1 |
| 0 | X | X | X | X | 38.4K Baud |
X | X | X |
| X | 0 | X | X | X | 8 Data Bits * |
X | X | X |
| X | 1 | X | X | X | 7 Data Bits |
X | X | X |
| X | X | 0 | X | X | Smart Switch Mode * |
X | X | X |
| X | X | 1 | X | X | Smart Switch and |
|
|
|
|
|
|
|
|
| Port Combiner Mode |
X | X | X |
| X | X | X | 0 | X | 3 Char. Command * |
X | X | X |
| X | X | X | 1 | X | 4 Char. Command |
X | X | X |
| X | X | X | X | 0 | Port Select Test Off * |
X | X | X |
| X | X | X | X | 1 | Port Select Test On |
|
| 0 | = OFF | 1 = ON | X = DON'T CARE | ||||
|
|
|
|
| * = FACTORY DEFAULT |
Port Configuration
The 232D4SS8 has a Master port and eight selectable ports labeled "A" through "H". Refer to “Rear View”. The Master port should be connected to the
Master Port
The Master port can be configured by the user as a DCE or a DTE port. In order to determine the proper Master port configuration of the 232D4SS8 it is necessary to have a basic understanding of the terms DCE and DTE.
4 | Documentation Number 232D4SS84502 Manual |
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph