Hobart HM1200 manual Replacing the Cavity Light Bulb, Service

Page 16

MAINTENANCE

REPLACING THE CAVITY LIGHT BULB

If the Cavity Light Bulb burns out, you can replace it yourself.

CAVITY LIGHT COVER

WARNING: UNPLUG ELECTRICAL POWER CORD BEFORE PERFORMING ANY CLEANING OR MAINTENANCE.

Unscrew the screw on the Cavity Light Cover located on the left side of the cabinet (Fig. 7).

Replace the old bulb with a new 115 – 125 V, 20 W bulb. Use same size and type.

Replace the Cavity Light Cover (turn screw until snug).

Fig. 7

TROUBLESHOOTING

FAILURE CODES

POSSIBLE CAUSE

SUGGESTED ACTION

 

 

 

 

Overcooked food.

Unplug oven to stop beep. Wait for oven to cool

 

and reset. If food ignites, do not open door.

F01

Exhaust air temperature too

If normal operation does not resume, contact

 

high.

 

service and report the Failure Code number.

 

 

 

 

 

F05, F33, F34, F44,

 

Unplug. Wait at least 1 minute. Reconnect.

Problem with circuit.

If normal operation does not resume, contact

F81, F82, F86, F87

 

service and report the Failure Code number.

 

 

 

 

 

NOTE: The above codes do not indicate all the possible failures.

SERVICE

Contact your local Hobart-authorized service office for any repairs or adjustments needed on this equipment. Service contracts are available on this and other Hobart products.

FORM 34726 (Nov. 2001)

– 16 –

PRINTED IN U.S.A.

Image 16
Contents Model HM1200 Microwave Oven Important Safety Instructions Page Radio Interference UnpackingStacking TWO Ovens ONE on TOP of the Other LocationSeal Oven Base to Countertop Electrical Connection Grounding InstructionsOperation Display and KeypadTo resume cooking, close the door and press Start Manual HeatingProgramming Memory Keys Programming Memory Keys for Single PortionsCustom Programming Key for Multiple Portions Cooking Using a Programmed Memory KEY Double Portion KEY Program Unlock Program LockList Memory Programming Beep Tone Loudness Programming Beep Tone DurationDisplaying the Total Hours Displaying the Cycle CountBringing a CUP of Water to Boil Cleaning the AIR Filter CleaningCleaning the Spatter Shield Service Replacing the Cavity Light Bulb