INSTALLATION
Immediately after unpacking the dishwasher, check for possible shipping damage. If the machine is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
Prior to installation, test the electrical service to make sure it agrees with the specifications on the machine data plate.
LOCATION AND LEVELING
The dishwasher must be installed per the drawings on pages 4 – 6. Stainless steel is the recommended material for the table. The table should be a convenient height for the operator. The dishwasher should be level, both
PLUMBING CONNECTIONS
WARNING: PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY, AND PLUMBING CODES.
The plumber who connects this machine is responsible for making certain that incoming water lines are THOROUGHLY FLUSHED OUT before connecting to any manual valve or solenoid valve.
This
Manual valves or solenoid valves fouled by foreign matter, and any expenses resulting from this fouling, are NOT the responsibility of the manufacturer.
Hot Water Connection
Water must be proper hardness. Recommended hardness range is 4 – 6 grains / gallon. Lower hardness can promote corrosion, higher hardness may cause excessive formation of lime scale. A line strainer should be installed in the water supply line at the time of installation. The line strainer prevents frequent clogging of the rinse nozzles and requires only occasional cleaning.
The water supply connection point has a 1/2" NPT internal thread (see FILL CONNECTION, Fig. 1). The water supplied to this machine must be 180°F and have a flow pressure of 20 – 25 psig for most effective rinsing. CAUTION: The water pressure regulator must have a relief
Drain Connection
Connect the drain to the sewer from the 11/4" NPT tapped connection, provided. Use a 11/4" – 11/2" coupling to provide 11/2" line to sewer. If a grease trap is required by code, it should have a minimum flow capacity of approximately 28 gallons per minute.
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT THE ELECTRICAL POWER SUPPLIES AND PLACE A TAG AT THE DISCONNECT SWITCHES INDICATING THAT YOU ARE WORKING ON THE CIRCUITS.
Make the main electrical connection at the motor junction box (Fig. 1) where a knockout for 1/2" conduit is provided. Make the electrical connection for the electric heater circuit at the electric box for the electric heater where a knockout for 1/2" conduit is provided. Refer to the wiring diagram attached to the inside of the control box cover. All electrical supply lines to the machine must be disconnected when disconnection is required.