Jenn-Air CVGX242 Save These Instructions, Ducting Considerations, Important Safety Instructions

Page 4
Important Safety Instructions

Important Safety Instructions

24.This appliance has been tested for safe performance

using conventional cookware. Do not use any devices or accessories that are not specifically recommended in this

manual. Do not use eyelid covers for the surface burners or stovetop grills. The use of devices or accessories that are not expressly recommended in this manual can create serious safety hazards, result in performance problems and reduce the life of the components of the appliance.

25.Before servicing shut off electrical power supply to appliance.

26.Keep vent area unobstructed when in use.

WARNING

Electrical Grounding Instructions

The appliance is equipped with a three-prong _ grounding plug for your protection against

shock hazard

and should be plugged _

._"l_

directly into

a properly grounded /_

_

three-prong receptacle. Do not cut or [If----

remove the grounding prong from this plug.

IMPORTANTSAFETY NOTIC]

AND WARNING

The California Safe Drinking Water and Toxic Enforcen- Act of 1986 (Proposition 65) requires the Governor of C fornia to publish a list of substances known to the State

Californiato cause cancer or reproductive harm, andrequ businesses to warn customers of potential exposures to s

substances.

Users of this appliance are hereby warned that the burninl

gas can result in lowqevel exposure to some of the lk, substances, including benzene, formaldehyde and soot,,

primarily to the incomplete combustion of natural gas

liquid petroleum (LP) fuels. Properly adjusted burners _ minimize incomplete combustion. Exposure to these s

stances can be minimized by properly venting the cookto] the outdoors.

SAVE THESE INSTRUCTIONS

Ducting

Ducting Considerations

Jenn-Air's ventilation system is designed to capture both

cooking fumes and smoke from the cooktop surface. If the

system does not, these are some ducting installation situations to check:

6"diameter round or 3 Jh" x 10"rectangular ducting should be used for duct lengths 10'-60'. Note: 5" diameter round dueting must be used for venting straight out the back of the cooktop and directly through the wall for 10' or less.

No more than three 90 ° elbows should be used. Distance between elbows should be at least 18".

,Recommended Jenn-Air wall cap MUST be used. Me sure damper moves freely when ventilation system

operating.

There should be a minimum clearance of 6" for cook! installed near a side wall.

If there is not an obvious improper installation, there may a concealed problem such as a pinched joint, obstruction the pipe, etc. Installation is the responsibility of the instal and questions should be addressed first by the installer. _I installer should very carefully check the ducting installati instructions.

Image 4
Contents For Future For Future Assistance nofoUowedexactt lyorexplo, maysionresultConsumer Information 403West Fourth Street North Newton, IAImportant Safety Instructions Read before operating yourcooktop gas leakSAVE THESE INSTRUCTIONS Ducting ConsiderationsImportant Safety Instructions IMPORTANTSAFETY NOTICUsing Your Cooktop qettln, the ControlsBurner Heat Settings CooktopVentilation System Operating During Power FailureCare and Cleaning of the VentilationSystemCare and Cleaning Cleaning Care andBefore You Call For Service ¢ contactan authorizedJenn-AirServiceContractor