Danish Interpretation Systems | User Manual |
DC 6990P Conference Units – CU 6010/6011
The following table shows the maximum number of | Central Unit or on each output on an EX 6010 | ||||
units, which can be connected to each of the four | Extension Unit or on the output of a PS 6000. | ||||
outputs (A1, A2, B1 or B2) on a CU 6010/6011 |
|
|
| ||
|
|
|
|
|
|
| Length of Feeding Cable | Length of inter connecting | Total cable length | Max. number of |
|
| Type CAT5 AWG24 | Cable, Type CAT5 AWG24 |
| DC 6990P pr output |
|
|
|
|
|
|
|
| 10 m | 1 m | 35 m | 26 |
|
| 30 m | 1 m | 53 m | 24 |
|
| 50 m | 1 m | 70 m | 21 |
|
| 100 m | 1 m | 112 m | 13 |
|
| 150 m | 1 m | 158 m | 9 |
|
| 10 m | 2 m | 56 m | 25 |
|
| 30 m | 2 m | 72 m | 22 |
|
| 50 m | 2 m | 90 m | 19 |
|
| 100 m | 2 m | 124 m | 13 |
|
| 150 m | 2 m | 166 m | 9 |
|
DC 6990P Conference Units – CU 6005
The following table shows the maximum number of units, which can be connected to the two outputs (A1 and A2) simultaneously on a CU 6005 in total
If only one chain is used the information in the above table must be used.
Length of Feeding Cable | Length of inter connecting | Total cable length | Max. number of |
Type CAT5 AWG24 | Cable, Type CAT5 AWG24 |
| DC 6990 for both outputs |
|
|
|
|
10 m | 1 m | 2x34 m | 2x15 |
30 m | 1 m | 2x43 m | 2x14 |
50 m | 1 m | 2x62 m | 2x13 |
100 m | 1 m | 2x110 m | 2x11 |
150 m | 1 m | 2x158 m | 2x9 |
10 m | 2 m | 2x36 m | 2x14 |
30 m | 2 m | 2x54 m | 2x13 |
50 m | 2 m | 2x90 m | 2x12 |
100 m | 2 m | 2x118 m | 2x10 |
150 m | 2 m | 2x164 m | 2x8 |
Manual 01 18 04438 | 27 |
|