The following table shows the maximum number of

Central Unit or on each output on an EX 6010

units, which can be connected to each of the four

Extension Unit or on the output of a PS 6000.

outputs (A1, A2, B1 or B2) on a CU 6010/6011

 

 

 

 

 

 

 

 

 

 

Length of Feeding Cable

Length of inter connecting

Total cable length

Max. number of

 

 

Type CAT5 AWG24

Cable, Type CAT5 AWG24

 

DC 6990P pr output

 

 

 

 

 

 

 

 

10 m

1 m

35 m

26

 

 

30 m

1 m

53 m

24

 

 

50 m

1 m

70 m

21

 

 

100 m

1 m

112 m

13

 

 

150 m

1 m

158 m

9

 

 

10 m

2 m

56 m

25

 

 

30 m

2 m

72 m

22

 

 

50 m

2 m

90 m

19

 

 

100 m

2 m

124 m

13

 

 

150 m

2 m

166 m

9

 

DC 6990P Conference Units – CU 6005

The following table shows the maximum number of units, which can be connected to the two outputs (A1 and A2) simultaneously on a CU 6005 in total

If only one chain is used the information in the above table must be used.

Length of Feeding Cable

Length of inter connecting

Total cable length

Max. number of

Type CAT5 AWG24

Cable, Type CAT5 AWG24

 

DC 6990 for both outputs

 

 

 

 

10 m

1 m

2x34 m

2x15

30 m

1 m

2x43 m

2x14

50 m

1 m

2x62 m

2x13

100 m

1 m

2x110 m

2x11

150 m

1 m

2x158 m

2x9

10 m

2 m

2x36 m

2x14

30 m

2 m

2x54 m

2x13

50 m

2 m

2x90 m

2x12

100 m

2 m

2x118 m

2x10

150 m

2 m

2x164 m

2x8

Manual 01 18 04438

27

 

Image 27 Contents
DCS Danish Interpretation Systems List of Contents Microphone conference system with 3+1 ch Labels Important safety instructionsInstallation precautions CompliancyWarranty Cleaning & RepackingDescription of the DCS 6000 system FeaturesVoting equipment System componentsCentral equipment etc Interpreter equipmentGeneral description FeaturesFeature License CU 6010 Central UnitFront plate controls User Controls, indications & connectors Front plate layoutIndications SymbolsSystem settings Back Panel Layout Back Panel ConnectorsAudio control Delegate setup Values from 1 to 10 seconds in 0.5 sec step Interpretation setup Units info Ambient microphoneRS232 setup Security setupConfiguration Firmware info menu License info menuNormal Operation Powering up Schematics volume/gain settingsUse with SW CU 6011 Central Unit CU 6010 Orignal Audio Volume ControlCU 6005 Central Unit Other Normal OperationBuilt into 19 Racks General guidelinesMaximum number of units to be connected CM/DM 60x0P Chairman/Delegate Units CU 6010/6011CM/DM 60x0P Chairman/Delegate Units CU CM/DM 6560F Chairman/Delegate Units CU 6010/6011 CM/DM 6060F/6510F Chairman/Delegate Units CU 6010 /6011DC 6990P Conference Units CU DC 6990P Conference Units CU 6010/6011Is 6132P Interpreter Units CU 6010/6011 CS 6032F Channel Selector w/back light on CU 6010 /6011 Is 6132P w/JB 6004 and LS 6032 CU 6010/6011Small conference microphone system with CU Typical schematicsDanish Interpretation Systems Danish Interpretation Systems Danish Interpretation Systems Small system with SW 6000 Conference Management Software Large system with SW 6000 Conference Management Software RS 422 Serial connection Technical appendixCabling RS 232 Serial connectionAccessories not supplied Analog Audio, Line output XLR3 maleAnalog Audio, Line Input XLR3 female System performance with CU Technical specifications Digital SectionAnalogue Section GeneralDanish Interpretation Systems