Listen Technologies CU 6005, CU 6011 user manual Is 6132P Interpreter Units CU 6010/6011

Page 28

Danish Interpretation Systems

User Manual

MU 6040C/D and MU 6042D without connected loudspeaker – CU 6010/6011

This table shows the maximum number of MU 6040 Microphone Units, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011 Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.

The numbers are valid with no audio in loudspeaker (no loudspeaker connected to each unit). If loudspeakers are used, then use the figures for CM/DM 60x0P above.

Length of Feeding Cable,

Cable length between

Total cable length

Max. number of

Type CAT5 AWG24

each MU 6040

 

MU 6040

 

 

 

 

10 m

2 m

168 m

80

30 m

2 m

178 m

75

50 m

2 m

188 m

70

100 m

2 m

200 m

51

150 m

2 m

200 m

26

100 m

1 m

151 m

52

150 m

1 m

191 m

42

IS 6132P Interpreter Units – CU 6010/6011

The tables below shows the maximum number of IS 6132P Interpreter Sets, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011 Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.

The numbers are with no audio in loudspeaker (no loudspeaker connected to each unit).

If loudspeakers are used, then use the figures for CM/DM 60x0P above.

Note: The number of units is dependant of how many interpreter sets there are per booth (or language), as there only can be one set switched ON per language (channel).

Length of Feeding Cable,

Length of inter-connecting Cables,

Max. number of units pr output

Type CAT5 AWG24

Type CAT5 AWG24

All ON ½ ON 1/3 ON

 

 

 

 

 

 

10m

2

m

54

x

x

30m

2

m

49

57

60

50m

2

m

44

51

x

100m

2

m

35

40

x

150m

2

m

25

30

x

28

Manual 01 18 04438

 

Image 28 Contents
DCS Danish Interpretation Systems List of Contents Microphone conference system with 3+1 ch Important safety instructions Installation precautionsCompliancy LabelsCleaning & Repacking WarrantyFeatures Description of the DCS 6000 systemSystem components Central equipment etcInterpreter equipment Voting equipmentFeatures Feature LicenseCU 6010 Central Unit General descriptionUser Controls, indications & connectors Front plate layout Front plate controlsSymbols IndicationsBack Panel Layout Back Panel Connectors System settingsAudio control Delegate setup Values from 1 to 10 seconds in 0.5 sec step Interpretation setup Ambient microphone Units infoSecurity setup RS232 setupConfiguration License info menu Firmware info menuSchematics volume/gain settings Normal Operation Powering upUse with SW CU 6010 Orignal Audio Volume Control CU 6011 Central UnitCU 6005 Central Unit Normal Operation Other General guidelines Built into 19 RacksCM/DM 60x0P Chairman/Delegate Units CU 6010/6011 Maximum number of units to be connectedCM/DM 60x0P Chairman/Delegate Units CU CM/DM 6060F/6510F Chairman/Delegate Units CU 6010 /6011 CM/DM 6560F Chairman/Delegate Units CU 6010/6011DC 6990P Conference Units CU 6010/6011 DC 6990P Conference Units CUIs 6132P Interpreter Units CU 6010/6011 Is 6132P w/JB 6004 and LS 6032 CU 6010/6011 CS 6032F Channel Selector w/back light on CU 6010 /6011Typical schematics Small conference microphone system with CUDanish Interpretation Systems Danish Interpretation Systems Danish Interpretation Systems Small system with SW 6000 Conference Management Software Large system with SW 6000 Conference Management Software Technical appendix CablingRS 232 Serial connection RS 422 Serial connectionAnalog Audio, Line output XLR3 male Accessories not suppliedAnalog Audio, Line Input XLR3 female Technical specifications Digital Section Analogue SectionGeneral System performance with CUDanish Interpretation Systems