Danish Interpretation Systems | User Manual |
Technical specifications
Digital Section | Connectors |
Sound quality .........24 bit audio @ 32 kHz sampling frequency
Analogue Section
Floor output signal type | electronically balanced |
Nominal output level | |
Max. output level | 3.5V RMS ∼ +13 dBm |
Line input signal type | electronically balanced |
Nominal input level (adjustable) | |
............................... +6 to | |
Max. input level | +30 dBm (25V RMS) |
Line input impedance | |
Frequency response | |
Signal to noise ratio: | >85 dBA |
Total harmonic distortion: | < 0.1% |
General
Power consumption | max. 150W (CU 6005) | |
....................................................... | max. 600W (CU 6010/6011) | |
max. 30A@115V or max. 60A@230V | ||
Mains voltage: | 100 - 240V, 50 - 60Hz | |
Supply voltage for units | ||
(for: A1 plus A2) | 48V/125W (CU 6005) | |
(for each: A1, A2, B1, B2) | 48V/125W (CU 6010/6011) | |
Temperature to guarantee specified performance | ||
.............................. | 5 Deg C. to 40 Deg C. (35 to 80% humidity) | |
Storage temp | ||
Weight | 5.7 kg (CU 6005) | |
............................................................... | 6.2 kg (CU 6010/6011) | |
Dimensions (W x H x D) | 425 (483) x 87 x 317 (357) mm | |
Dimensions in bracket are including 19” brackets | ||
Slot dimensions (W x H x D) | 180 x 38 x 120 mm (CU 6005) | |
Accessories supplied | User manual | |
................................................................................. | Mains cable | |
.......................................................... | 5 pieces termination plugs |
DCS 6000 network chain | ............................... RJ45 |
..................................................................... | 2 pieces (CU 6005) |
............................................................ | 4 pieces (CU 6010/6011) |
Maximum number of units to be connected to the two | |
outputs in total on a CU 6005 or to each chain of the four | |
outputs on a CU 6010/6011: |
|
MU 6040 Microphone Units | up to 80 pieces |
DM/CM 60x0P Delegate/Chairman Unit ...up to 42 pieces | |
IS 6132P Interpreter Set | up to 54 pieces |
CS 6032F Channel Selector | up to 110 pieces |
The actual maximum number of units depends on the | |
length of the feeding cable and interconnection cables | |
Line output | XLR3 male connector |
Line input | XLR3 female connector |
RS 232 (with hardware handshake) | |
RS 422 (with hardware handshake | |
................................either the RS232 or the RS422 can be used | |
System performance with CU | |
6005/6010/6011 as central unit | |
Max. number of conference units | 3800 (CU 6010/6011) |
Max. number of conference units | 500 (CU 6005) |
Max. number of units (excl. CS) | 4000 |
Max. number of IS 6xxx in one booth | 32 |
Max. number of IS 6xxx | 150 |
Max. number of AO 6004/6008 | 20 |
Max. number of CS 6032 | practically unlimited |
Max. number of languages | 16 (CU 6005) |
.................................................................... | 31 (CU 6010/6011) |
Max number of open microphones | 8 |
The DCS 6000 system conforms to all relevant standards - | |
e.g. IEC 914, ISO 4043, and ISO 2603 | |
Specifications are subject to change without notice. |
38 | Manual 01 18 04438 |
|