TROUBLESHOOTING SUGGESTIONS
|
|
|
SYMPTOM | POSSIBLE CAUSE | SUGGESTED REMEDY |
|
|
|
Water won’t heat | Brewer unplugged or circuit | Check power supply cord |
| breaker tripped | Check / reset circuit breaker |
| Thermostat set too low | Set for desired temperature |
|
|
|
| Allow to cool | |
|
| Reset |
| Damaged internal component or | Examine wiring & connectors, |
| wiring | thermostat and heating element |
|
| Repair/replace as needed |
|
|
|
Coffee level too high or low | Timer out of adjustment | Adjust timer |
|
|
|
Brew chamber overflows | Too many filter papers or wrong | Use one (1) genuine Bloomfield |
| filter paper | filter per brew |
|
|
|
| Brew chamber dispense hole | Thoroughly clean brew chamber |
| plugged |
|
|
|
|
| Too much tea leaves | Adjust tea amount |
|
|
|
Sprays water from brew head | Spray gasket improperly | Check/reinstall gasket on |
| installed | INSIDE of brew head |
|
|
|
| Spray disk plugged | Clean spray disk |
|
|
|
No brew | Water supply OFF | Turn water supply ON |
|
|
|
| Water line strainer plugged | Clean strainer (see pg. 14) |
|
|
|
| Water filter (if used) plugged | Replace filter element |
|
|
|
| Bad BREW switch | Replace switch |
|
|
|
| Damaged internal component or | Examine wiring & connectors, |
| wiring | brew switch and solenoid |
|
| Repair/replace as needed |
|
|
|
No flow from dilution nozzle | Dilution ratio out of adjustment | Adjust dilution ratio |
|
|
|
| Nozzle or tubing plugged | Disassemble, clean |
|
|
|
Poor coffee quality | Water not hot enough | Adjust water temp |
|
|
|
| Dilution ratio out of adjustment | Adjust dilution ratio |
| Keep brewer and dispenser clean. Install a taste and odor filter in | |
| water supply, and replace cartridges regularly. Use a quality tea. | |
| Use proper amount of tea per brew. | |
|
|
|
|
|
|
SURVIVAL GUIDE |
|
|
| Keep a spare brewer available. |
|
| Due to the potential for injury, alternate methods of brewing tea are | |
| not recommended. |
|
8