SERVICING INSTRUCTIONS (continued)
TEMPERATURE ADJUSTMENT
PRECAUTIONS: | Disconnect brewer from electric power. |
| Allow brewer to cool. |
FREQUENCY: | As required to adjust delivered volume |
TOOLS: | Phillips head screwdriver |
| Satellite or other container to calibrate volume |
1.Press HEATER ON/OFF switch to OFF. Turn POWER switch on back of brewer OFF.
2.Remove TOP PANEL. Operating controls are accessible through the top panel only.
3.Remove one of the plugs in the tank cover and insert a thermometer of known accuracy.
4.Locate the CONTROL THERMOSTAT on the right side of the top housing:
Turn CLOCKWISE to increase temperature
Turn
5.Turn POWER switch ON. Press HEATER ON/OFF switch to ON.
6.Allow the brewer to come up to brewing temperature. When
CAUTION:
SHOCK HAZARD
Live electrical circuits are exposed during this procedure. Use care to avoid uninsulated electrical connectors.
NOTE:
Optimum brewing temperature range is 195ºF to 205ºF (90ºC to 96ºC).
IMPORTANT:
Amechanical thermostat will maintain temperature within ±5ºF. To prevent boiling water in the brewer, thermostat should be adjusted to a maximum temperature equal to the local boiling temperature minus 5ºF. Adjustments to be performed by qualified technician only.
NOTE:
1/8 turn = approx 10ºF (5.5ºC)
671 76601 Owners Manual 9221 Dual Satellite Brewer
7.When desired temperature is achieved, remove thermometer, replace tank plug and reinstall top panel.
Procedure is complete