Installation
The climate classification can be found on the rating plate, which is located at the left on the inside of the appliance.
The following table shows which ambient temperature is correct for each climate classification:
Climate classification | for an ambient temperature of |
SN | +10 to +32 °C |
N | +16 to +32 °C |
ST | +18 to +38 °C |
T | +18 to +43 °C |
|
|
The freezer needs ventilation
Air is fed under the door through the vent slots in the base and is exhausted upwards along the back wall. To ensure proper air circulation never cover or alter the vent openings.
Important! If the appliance is installed under, for example, a hanging cabinet, a clearance of at least 10 cm between the top of the appliance and the cabinet above it must be maintained.
Please check whether, after installing your appliance and especially after reversing the door, the door seal fits tightly. A badly fit- ting door seal may lead to heavy frosting and a higher power consumption (see also “What to do if ...“).
Appliance Alignment
01. The appliance must be level. Please compensate for unevenness in the floor by turning the two adjustable feet at the front.
818 35 | 9 |