D - | Installation & Warnings |
GAS TRANSFORMATIONS AND ADJUSTMENTS
Replacing the nozzles
If the equipment is adjusted for a type of gas that is different from the original, it is necessary to replace the burner nozzles as well. The nozzles used to replace the original must be in accordance with the table of the technical characteristics enclosed.
To remove the racks and burners by means of a straight spanner ‘L’, unscrew the nozzle ‘U’ (Fig.8) and substitute it with the corresponding one and tighten the nozzle.
Adjusting the burners
The flame should always stay alight when the burner is switched on, even if there is an abrupt shift from the maximum to minimum flame position. If the flame does not stay alight, adjust it as follows:
–Start the burner
–Turn the tap up to the minimum position (small flame)
–Remove the knob from the tap rod
–Using a
MAINTENANCE
Lubricating the taps
In the case of tap hardening, it is necessary to disassemble the tap and grease it.
–Unscrew the two screws that lock the head flange of the tap.
–Lift the gas adjusting cone and carefully clean it with gasoline or diluent.
–Spread a little
–Reassemble all of the parts with care.
Replacing the power supply cable
If the power supply cable needs to be replaced, it is necessary to use a cable with a section of 3x0.75mm2, type
NOTE:
The connection to the terminal board must be effected as shown in fig. 10 - 10A:
Brown cable L (phase)
Blue cable N (neutral)
7