AEG CGA 60 WOK, CGA 90 WOK, CGA 75 WOK Technical Diagrams, Technical Characteristics Table

Page 9

E -

Technical Diagrams

 

CGA 60 WOK

 

CGA 75 WOK

 

 

 

 

 

 

 

 

 

 

 

 

CGA 90 WOK

F -

 

Technical Characteristics Table

 

 

 

 

 

 

 

 

 

 

 

 

NORMAL

INJECTOR

TAPE BY

NOMINAL

 

BURNERS

 

PASS

HEAT INPUT

 

GAS

PRESSURE

DIAMETER

 

 

DIAMETER

MAX.

 

 

 

 

 

DESCRIPTION

 

mbar

1/100 mm

1/100 mm

MJ/h (Btu/h)

1

RAPID

PROPANE

28

92

42

11.6

(11000)

NATURAL

10

155

REG.

 

 

 

 

2

SEMI-RAPID

PROPANE

28

72

31

6.3

(6000)

NATURAL

10

120

REG.

 

 

 

 

3

AUXILIARY

PROPANE

28

55

27

3.2

(3000)

NATURAL

10

90

REG.

 

 

 

 

 

 

 

 

 

 

 

 

4

WOK

PROPANE

28

107

60

17.9

(17000)

NATURAL

10

175

REG.

 

 

 

 

The manufacturing firm refuses all responsibility for any possible imprecision in this booklet, due to misprints or clerical errors. It reserves the right to make all the changes that it will consider necessary in its own products, without affecting the essential characteristics of functionality and safety.

9

Image 9
Contents Gas Cooktop Contents EEC 73/23 e 93/68 Low Voltage EEC 89/109 Contact with foods Installation check and warningsBurners Cooking InstructionsEnameled Burner Caps CleaningStainless Steel Burners and racksModel Installation & WarningsFastening the top Gas ConnectionMaintenance GAS Transformations and Adjustments10/A Technical Characteristics Table Technical DiagramsPower MJ/h Power Btu/h Rapid burner Oakville, Ontario Canada L6H5V1 WarrantyAEG