CY7C1018CV33

Selection Guide

 

 

-10

-12

-15

Unit

Maximum Access Time

10

12

15

ns

 

 

 

 

 

Maximum Operating Current

Comm’l

90

85

80

mA

 

 

 

 

 

 

 

Ind’l

 

85

 

mA

 

 

 

 

 

 

Maximum Standby Current

 

5

5

5

mA

 

 

 

 

 

 

Maximum Ratings

(Above which the useful life may be impaired. For user guide- lines, not tested.)

Storage Temperature

–65°C to +150°C

Ambient Temperature with

 

Power Applied

–55°C to +125°C

Supply Voltage on VCC Relative to GND[2] ... –0.5V to + 4.6V DC Voltage Applied to Outputs[6]

in High-Z State

–0.5V to VCC + 0.5V

DC Input Voltage[2]

–0.5V to V + 0.5V

 

CC

Electrical Characteristics Over the Operating Range

Current into Outputs (LOW)

20 mA

Static Discharge Voltage

> 2001V

(per MIL-STD-883, Method 3015)

 

Latch-up Current

> 200 mA

Operating Range

Range

Ambient Temperature

VCC

Commercial

0°C to +70°C

3.3V ± 10%

 

 

 

Industrial

–40°C to +85°C

3.3V ± 10%

 

 

 

 

 

 

 

 

 

 

 

–10

 

–12

 

–15

 

Parameter

Description

Test Conditions

 

 

 

 

 

 

Unit

Min.

Max.

Min.

Max.

Min.

Max.

 

 

 

 

 

 

 

 

 

 

 

VOH

Output HIGH Voltage

VCC = Min.,

 

2.4

 

2.4

 

2.4

 

V

 

 

IOH = – 4.0 mA

 

 

 

 

 

 

 

 

VOL

Output LOW Voltage

VCC = Min.,

 

 

0.4

 

0.4

 

0.4

V

 

 

IOL = 8.0 mA

 

 

 

 

 

 

 

 

VIH

Input HIGH Voltage

 

 

 

 

 

2.0

VCC + 0.3

2.0

VCC + 0.3

2.0

VCC + 0.3

V

VIL

Input LOW Voltage[2]

 

 

 

 

 

–0.3

0.8

–0.3

0.8

–0.3

0.8

V

IIX

Input Leakage

GND < VI < VCC

 

–1

+1

–1

+1

–1

+1

A

 

Current

 

 

 

 

 

 

 

 

 

 

 

 

IOZ

Output Leakage

GND < VI < VCC,

 

–1

+1

–1

+1

–1

+1

A

 

Current

Output Disabled

 

 

 

 

 

 

 

 

ICC

VCC Operating

VCC = Max.,

Comm’l

 

90

 

85

 

80

mA

 

Supply Current

IOUT = 0 mA,

 

 

 

 

 

 

 

 

 

Ind’l

 

 

 

85

 

 

mA

 

 

f = fMAX = 1/tRC

 

 

 

 

 

 

 

 

ISB1

Automatic CE

Max. VCC,

 

> VIH

Comm’l

 

15

 

15

 

15

mA

CE

 

 

 

 

Power-down Current

VIN > VIH or

 

 

 

 

 

 

 

 

 

Ind’l

 

 

 

15

 

 

mA

 

—TTL Inputs

VIN < VIL, f = fMAX

 

 

 

 

 

 

 

 

ISB2

Automatic CE

Max. VCC,

 

 

 

Comm’l

 

5

 

5

 

5

mA

 

Power-down Current

CE > VCC

– 0.3V,

 

 

 

 

 

 

 

 

 

Ind’l

 

 

 

5

 

 

mA

 

—CMOS Inputs

VIN > VCC

– 0.3V,

 

 

 

 

 

 

 

 

 

 

or VIN < 0.3V, f = 0

 

 

 

 

 

 

 

 

Capacitance[3]

Parameter

Description

Test Conditions

Max.

Unit

 

 

 

 

 

CIN

Input Capacitance

TA = 25°C, f = 1 MHz,

8

pF

 

 

VCC = 3.3V

 

 

COUT

Output Capacitance

8

pF

 

Notes:

2.VIL (min.) = –2.0V for pulse durations of less than 20 ns.

3.Tested initially and after any design or process changes that may affect these parameters.

Document #: 38-05131 Rev. *D

Page 2 of 7

[+] Feedback

Page 2
Image 2
Cypress CY7C1018CV33 Selection Guide, Maximum Ratings, Electrical Characteristics Over the Operating Range, Capacitance3