Antunes, AJ VCT-1000 owner manual Troubleshooting, Problem Possible Cause Corrective Action

Page 15

VERTICAL CONTACT TOASTER

TROUBLESHOOTING

WARNING

To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equipment should be performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will be exposed.

Problem

Possible Cause

Corrective Action

No heat and conveyor

Toaster is installed incorrectly.

Perform the installation and operating proce-

belts do not move.

 

dures found in the Installation and Operation

 

 

sections of this manual.

 

Inoperable power cord or Rocker

Check receptacle for correct voltage (see the

 

Switch.

Specifications section of this manual).

 

 

If necessary, contact your maintenance person

 

 

or Authorized Service Agency for service.

 

Hi-Limit Control is tripped.

Reset the Hi-Limit Control (see Figure 6 in the

 

 

Operations section of this manual).

 

Wiring Problem.

Contact your maintenance person or Authorized

 

 

Service Agency for service.

No heat but Conveyor

Wiring Problem.

Contact your maintenance person or Authorized

Belt Chains move.

 

Service Agency for service.

Inoperative Platen.

 

Inoperable Thermostat

 

Platen is hot but

Heat Shield not installed.

Install Heat Shield (Figure 2)..

Conveyor Belt Chains do

 

 

Conveyor Safety Interlock switch not

Re-install the Heat Shield correctly so that the

not rotate.

activated by the heat shield..

Heat Shield applies appropriate pressure on the

 

 

Conveyor Safety Interlock switch.

 

Spring Tensioner Assembly or Roller

Replace Spring Tensioner or Roller Tensioners if

 

Tensioner is damaged or missing.

damaged or missing.

 

Conveyor Belt Chain links too loose.

Adjust Conveyor Belt Chain length as described

 

 

in the Maintenance section of this manual.

 

Inoperable Drive Motor.

Contact your maintenance person or Authorized

 

 

Service Agency.

 

Loose Drive Motor Sprocket

 

Setscrew.

 

 

Drive Motor Chain has fallen off

 

 

sprocket(s).

 

 

Inoperable Safety Interlock Switch.

 

Conveyor Belts Chains

Conveyor Belt Chains installed incor-

Install Conveyor Belt Chains to match Figure 11.

hesitate to rotate and/or

rectly.

Be sure that the ends of the hooks are facing

“skip” on sprockets.

 

down.

 

Conveyor Belt Chains too loose.

Adjust Conveyor Belt Chain length as described

 

 

in the Maintenance section of this manual.

 

Spring Tensioner Assembly or Roller

Replace Spring Tensioner Assembly or Roller

 

Tensioner is damaged or missing.

Tensioners if damaged or missing.

P/N 1010807 Rev. E 06/06

15

Image 15
Contents Vertical Contact Toaster Owner Information Table of ContentsOwner Information Service/Technical AssistanceImportant Safety Information Electrical Ratings Important Safety InformationSpecifications Electrical Cord & Plug ConfigurationsDimensions SpecificationsInstallation UnpackingAssembling the Unit Installing the Optional Belt Wraps and Roller Tensioners InstallationEquipment Setup Safety Features OperationOperating Instructions Daily MaintenanceReplacing the Release Sheet Every 4 6 weeks MaintenanceRemoving Conveyor Belt Chain Conveyor Belt ChainsReplacing the Optional Roller Tensioners Replacing the Spring TensionersMeasuring the Optional Roller Tensioners Problem Possible Cause Corrective Action TroubleshootingTroubleshooting Pictorial Wiring Diagram VCT-1000 Wiring DiagramParts Identification Replacement PartsReplacement Parts Vertical Contact Toaster 1010807 Rev. E 06/06 Description Qty Mechanical Butter Wheel Kit Model Optional Parts VCT-1000Limited Warranty