Kathrein MVG 10 manual Technical appendix, Technical data

Page 27

Technical appendix

Technical data

Frequency range:

4.0 MHz...1000 MHz

Frequency adjustment:

50 kHz

Frequency resolution:

62.5 kHz

Display:

LCD alphanumeric 2 x 16

 

characters, bar chart; illuminated

Adjustment:

direct frequency and channel

 

entry; +/- step buttons

Sweep ranges:

10 ranges with start/stop

 

and frequency step entry

Channel hopping:

10 ranges with start/stop

 

and channel step entry

Output signal level:

36 dBµV ...100 dBµV

Signal level accuracy:

±2dB

Signal level resolution:

0.1 dB

Interference level:

40 dBµV (to 90 dBµV -

 

output signal level)

Noise generator:

4.0 MHz...1000 MHz,

 

Standing wave ratio ±2dB

Noise level:

85 dBµV (BW 1MHz)

Noise level resolution:

1 dB

Output:

75 BNC socket

Modulation (double-sideband):

Test picture, SCART-CVBS

 

SCART RGB

 

FM sound modulation

Power supply:

Internal lead-acid battery

 

12 V/2.8 Ah

 

External mains adaptor

 

for operating and charging

 

230 V ~ /50-60 Hz

Weight:

approx. 3 kg (incl. leather bag)

Dimensions, H x W x D:

90(115) x 162 x 235 mm³

 

() = incl. bag accessory

EMC/EMD:

CE

Included in delivery:

Leather bag with carry strap,

 

charger

27

Image 27
Contents Video Sweep Generator MVG Page Preface Page Contents Validity of handbook Safety notesGeneral safety notes Symbols usedConnections Use in accordance with intended purposeMechanical durability System description and usage Measurement principleReturn path measurement Downstream measurement 47…860 MHz Upstream measurement 4.0…80 MHzUpstream measurement Downstream measurement Views, connections and controls ·  Button functionsSystem settings OffEnter Setting not possible Set signal level Noise generatorSet bandwidth Signal generator Select Signal generatorSet transmission frequency Enter channel Enter transmissionBy Enter Channel entrySweep generator Select Sweep generatorPlus Enter Tracking on/off Enter start frequencyEnter end frequency Step duration from one+ + Recall no Sweep generatorSelect Channel sweep Channel sweep generatorModulation Enter start channelEnter end channel Channel stepsChannelSweep Accu 100 % Channel sweep generator Recall Technical appendix Technical data936.2879/-/1105/ZWT/e Technical data subject to change

MVG 10 specifications

The Kathrein MVG 10 is a state-of-the-art measurement system designed for the analysis and optimization of modern mobile communication networks. Tailored for telecommunications engineers and network operators, the MVG 10 stands out due to its advanced features, superior technologies, and overall performance.

One of the main features of the Kathrein MVG 10 is its versatility in supporting multiple frequency bands. This measurement device is capable of analyzing frequency ranges from 10 MHz up to 6 GHz, making it suitable for a wide array of wireless communication standards including LTE, 5G, and Wi-Fi. This broad frequency support allows network operators to conduct comprehensive network assessments across different technologies, ensuring optimum performance in mixed environments.

The MVG 10 is equipped with state-of-the-art software tools that provide user-friendly interfaces for network analysis. The intuitive graphical display allows for the easy monitoring of key performance indicators such as signal strength, signal quality, and interference levels. Real-time data visualization enables engineers to identify issues quickly and make informed decisions, which is essential for maintaining high-quality network services.

In addition to its impressive frequency capabilities, the Kathrein MVG 10 features advanced measurement technologies such as MIMO (Multiple Input Multiple Output) capabilities. This allows for the analysis of spatial diversity in signal reception, essential for modern communication systems that rely on multiple antennas to enhance data throughput and reliability.

Moreover, the device supports geolocation features, enabling operators to pinpoint the location of specific transmission issues or user complaints effectively. This functionality not only increases the accuracy of network testing but also significantly reduces the time required for troubleshooting.

The compact and portable design of the MVG 10 ensures convenience for field engineers who need to perform measurements on-site. Its robust construction is built to withstand challenging environments, ensuring durability while maintaining high precision during measurements.

Overall, the Kathrein MVG 10 is an essential tool for telecommunications professionals. Its combination of versatile frequency support, advanced measurement technologies, and user-friendly features makes it an invaluable asset for optimizing mobile communication networks and delivering high-quality services to end users. In an era where connectivity is paramount, the MVG 10 stands out as a reliable solution for the demands of today's fast-paced telecommunications landscape.