Safety notes

Always observe the VDE safety regulations.

Observe the maximum permissible signal feed-in level.

Neither DC voltage nor low-frequency AC voltage may be applied to the RF port.

Only use fuses with the same cut-out characteristics. The unit is live even when not connected.

The unit may only be operated with all shielding covers fitted and when closed to prevent electromagnetic interference. Only use suitable shielded cable.

Improper use during mains operation is a risk to life!

Connections

Improperly connected connections can lead to operating faults or defects in the unit.

Use in accordance with intended purpose

The operator must ensure that

the measuring instrument is only used in accordance with its intended purpose.

the measuring instrument is only used when in good order and fully functional.

the safety and warning notes on the measuring instrument are not removed and remain legible.

Mechanical durability

The MVG 10 is designed for mobile usage and the mechanical demands associated with this. The MVG 10 should not be exposed to heavy mechanical stress such as being struck, knocked or dropped as this can cause damage to the unit.

Electronic equipment must not be disposed of in domestic waste. According to directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL of 27 January 2003 on waste electrical and electronic equipment, it must be disposed of professionally.

Please take this unit to a public collection point intended for this type of disposal at the end of its useful life.

7

Image 7
Contents Video Sweep Generator MVG Page Preface Page Contents Validity of handbook Safety notesGeneral safety notes Symbols usedUse in accordance with intended purpose ConnectionsMechanical durability Measurement principle System description and usageReturn path measurement Upstream measurement 4.0…80 MHz Downstream measurement 47…860 MHzUpstream measurement Downstream measurement Views, connections and controls ·  Button functionsOff System settingsEnter Setting not possible Noise generator Set signal levelSet bandwidth Select Signal generator Signal generatorSet transmission frequency Enter channel Enter transmissionBy Enter Channel entrySelect Sweep generator Sweep generatorPlus Enter Tracking on/off Enter start frequencyEnter end frequency Step duration from one+ + Recall no Sweep generatorSelect Channel sweep Channel sweep generatorModulation Enter start channelEnter end channel Channel stepsChannelSweep Accu 100 % Channel sweep generator Recall Technical appendix Technical data936.2879/-/1105/ZWT/e Technical data subject to change

MVG 10 specifications

The Kathrein MVG 10 is a state-of-the-art measurement system designed for the analysis and optimization of modern mobile communication networks. Tailored for telecommunications engineers and network operators, the MVG 10 stands out due to its advanced features, superior technologies, and overall performance.

One of the main features of the Kathrein MVG 10 is its versatility in supporting multiple frequency bands. This measurement device is capable of analyzing frequency ranges from 10 MHz up to 6 GHz, making it suitable for a wide array of wireless communication standards including LTE, 5G, and Wi-Fi. This broad frequency support allows network operators to conduct comprehensive network assessments across different technologies, ensuring optimum performance in mixed environments.

The MVG 10 is equipped with state-of-the-art software tools that provide user-friendly interfaces for network analysis. The intuitive graphical display allows for the easy monitoring of key performance indicators such as signal strength, signal quality, and interference levels. Real-time data visualization enables engineers to identify issues quickly and make informed decisions, which is essential for maintaining high-quality network services.

In addition to its impressive frequency capabilities, the Kathrein MVG 10 features advanced measurement technologies such as MIMO (Multiple Input Multiple Output) capabilities. This allows for the analysis of spatial diversity in signal reception, essential for modern communication systems that rely on multiple antennas to enhance data throughput and reliability.

Moreover, the device supports geolocation features, enabling operators to pinpoint the location of specific transmission issues or user complaints effectively. This functionality not only increases the accuracy of network testing but also significantly reduces the time required for troubleshooting.

The compact and portable design of the MVG 10 ensures convenience for field engineers who need to perform measurements on-site. Its robust construction is built to withstand challenging environments, ensuring durability while maintaining high precision during measurements.

Overall, the Kathrein MVG 10 is an essential tool for telecommunications professionals. Its combination of versatile frequency support, advanced measurement technologies, and user-friendly features makes it an invaluable asset for optimizing mobile communication networks and delivering high-quality services to end users. In an era where connectivity is paramount, the MVG 10 stands out as a reliable solution for the demands of today's fast-paced telecommunications landscape.