Sanyo MDF-793C, MDF-593C Temperature Recorder, Feeding of chart, Replacement of cell

Page 22

TEMPERATURE RECORDER

The figure below shows the description of a temperature recorder.

Warning indicator

Door

Time Temperature

Recording indicator

Pen holder lever

Cartridge

Feeding of chart

1.Open the door and let down the lever of the penholder; the pen point is apart from the chart. (Fig. 1)

2.Pull the cartridge out of the mounted position. (Fig. 2)

3.Set a new chart in place on the rear bottom of the cartridge. Set the hole on the chart in the cog of the chart driving assembly and feed the chart in the direction of the arrow by driving the cog wheel.

4.Set the chart according to the mark of day and time. (Fig. 3)

5.When mounting, lay down the cartridge first, and push into the mounting position with the groove set a the projection on the position.

6.Set up the cartridge and settle in position.

Fig. 1

Fig. 2

Fig. 3

Replacement of cell

Replace the dry cell once a year as follows:

1.Put up the penholder first, then pull out cartridge from the mounted position.

2.Reset the battery chamber cover with wire, on the bottom left side, and take out the cell.

3.Set a new cell by turning its anode to this side.

4.Shut the cover after exchanging cells. Mount the cartridge as before and lay down the penholder.

Cell

21

Image 22
Contents MDF-593C MDF-793C Contents Precautions for Safe Operation Symbol showsMay cause bad effect on your health or environment Maintenance. These may be harmful to your health Water Precautions for Safe Operation Page Page Environmental Conditions Freezer Components Lock Control panel coverBreak down or power failure at the power supply Control panelInstallation Installation siteRemove the packaging materials and tapes InstallationAdjust the leveling foot Fix the unitOperation after power failure START-UP of UnitRemote alarm terminal Temperature settingOperating Instructions Alarm temperature setting Setting of alarm resume time Alarm and safety functions Alarm and safety functionBack-up system Rough schemeFeeding of chart Temperature RecorderReplacement of cell Setting of back-up temperature PenholderControl Panel Temperature Recorder Cleaning of condenser filter Routine MaintenanceCleaning Defrosting of inside wallTrouble Shooting Disposal of Unit Removal of nickel-cadmium battery Recycle of NICKEL-CADMIUM BatteryLocation of a nickel-cadmium battery Handling of batterySpecifications PerformanceSafety check sheet CEM

MDF-593C, MDF-793C specifications

The Sanyo MDF-793C and MDF-593C are advanced laboratory refrigeration models designed for a variety of applications in research, medical, and industrial settings. Both units embrace cutting-edge technologies and engineering innovations to provide reliable performance while ensuring specimen preservation and optimal storage conditions.

One of the key features of the Sanyo MDF-793C is its ability to maintain a consistent temperature range from -10 to -30 degrees Celsius. This wide range allows users to store a variety of sensitive materials, including biological samples, medications, and vaccines. The unit is equipped with a microprocessor-controlled temperature management system, which offers precise temperature monitoring and control. Additionally, the unit includes a rapid cooling system that ensures quick recovery after door openings, minimizing temperature fluctuations that can compromise stored materials.

The MDF-593C, while slightly smaller in capacity, also offers impressive temperature control and stability. It is designed to have an internal temperature range of -10 to -25 degrees Celsius. Its compact design makes it suitable for labs with limited space, without compromising performance. Both models utilize environmental-friendly refrigerants, which align with current sustainability practices and regulations.

In terms of technological advancements, both models include digital displays that provide real-time temperature readings. These displays come with alarms that notify users of any aberrations, ensuring the highest levels of monitoring and security. The integration of a high-efficiency compressor not only supports rapid cooling but also contributes to lower energy consumption, making both the MDF-793C and MDF-593C cost-effective options for long-term use.

Another standout characteristic is the robust insulation used in the construction of both units. High-density polyurethane foam enhances thermal efficiency and minimizes energy loss. This feature is essential for maintaining optimal internal temperatures while reducing the overall operational costs associated with energy consumption.

Both models also feature adjustable shelving and user-friendly designs, allowing for easy organization and access to stored items. Their durable construction ensures reliability while a sleek external design allows them to fit seamlessly into various laboratory environments.

In summary, the Sanyo MDF-793C and MDF-593C are exemplary choices for those seeking efficient, reliable, and environmentally sustainable refrigeration solutions. Their advanced technologies, coupled with user-friendly features, make them essential tools in ensuring the integrity of valuable samples across various fields.