Sanyo MDF-C8V service manual Unqualified personnel may cause electric shock or fire

Page 40

PRECAUTIONS FOR SAFE OPERATION

WARNING

Do not use the unit outdoors. Current leakage or electric shock may result if the unit is exposed to

rain water.

Only qualified engineers or service personnel should install the unit. The installation by

unqualified personnel may cause electric shock or fire.

Install the unit on a sturdy floor and take an adequate precaution to prevent the unit from turning over. If the floor is not strong enough or the installation site is not adequate, this may result

in injury from the unit falling or tipping over.

Never install the unit in a humid place or a place where it is likely to be splashed by water.

Deterioration of the insulation may result which could cause current leakage or electric shock.

Never install the unit in a flammable or volatile location. This may cause explosion or fire.

Never install the unit where acid or corrosive gases are present as current leakage or electric

shock may result due to corrosion.

Always ground (earth) the unit to prevent electric shock. If the power supply outlet is not grounded, it will be necessary to install a ground by qualified engineers.

Never ground the unit through a gas pipe, water main, telephone line or lightning rod. Such

grounding may cause electric shock in the case of an incomplete circuit.

Connect the unit to a power source as indicated on the rating label attached to the unit. Use

of any other voltage or frequency other than that on the rating label may cause fire or electric shock.

Never store volatile or flammable substances in this unit if the container cannot be sealed. These

may cause explosion or fire.

Do not insert metal objects such as a pin or a wire into any vent, gap or any outlet on the unit.

This may cause electric shock or injury by accidental contact with moving parts.

Use this unit in safe area when treating the poison, harmful or radiate articles. Improper use

may cause bad effect on your health or environment.

Turn off the power switch (if provided) and disconnect the power supply to the unit prior to any repair or maintenance of the unit in order to prevent electric shock or injury.

Do not touch any electrical parts (such as power supply plug) or operate switches with a wet hand. This may cause electric shock.

37

4

Image 40
Contents MDF-C8V Effective models Contents Features Specifications ŶStructural specificationsŶControl specifications ŶPerformance specifications Dimensions %8Refrigeration circuit diagram Refrigeration circuit welding points 㪚㪐㩷Cooling unit parts Components on PCB Electrical Parts Compressor terminals layoutSpecification of sensor Wiring diagram Circuit diagram Connection on PCB CN3Control specification Key and SwitchTemperature control Temperature alarmOther function PV. Note Auto Return is not worked in F09 and F10Function mode F04 Purpose Simply passing through if entered by mistake Model code ‘003’ MDF-C8V Differential The point of compressor on and OFF Offset valueWhen the power is supplied without battery Remote alarm terminalSensor failure Other specifications Fan motor operation and compressor protectionParts layout Electric BOX Lower back side Test Data 䇭㪥㫆䇭㫃㫆㪸㪻䇭㪥㫆䇭㫃㫆㪸㪻 㪈㪈㪌㪭䇭㪍㪇㪟㫑䇭㪘㪫㪊㪌 䇭㪥㫆䇭㫃㫆㪸㪻 Collection and charge of refrigerant Page Page MDF-C8V Contents Introduction Precautions for Safe Operation Unqualified personnel may cause electric shock or fire Abnormal operation may cause electric shock or fire Precautions for Safe Operation Environmental Conditions Freezer Components Freezer Components Control panel Installation Site Installation Adjusting the leveling footRemoving the packaging materials and tapes Fixing the unitOperation after power failure START-UP of UnitChamber Temperature Setting KEY Lock FunctionAlarm Temperature Setting Alarm Temperature Setting Setting of Alarm Resume Time Change of Compressor Delay Time Remote Alarm Terminal Alarms & Safety Functions Alarms and safety functionsCleaning of cabinet Routine MaintenanceDefrosting Battery Replacement of Battery Location of a nickel-metal-hydride batteryRemoval of nickel-metal-hydride battery Handling of batteryTroubleshooting Malfunction Check/RemedyRecycle of battery Disposal of UnitEnglish GermanFrench SpanishItalian PortugueseDutch SwedishTemperature Recorder Option Installation of MTR-85H Temperature Recorder Option Installation of MTR-G85 Temperature Recorder Option BACK-UP System Option BACK-UP System Option Specifications MDF-C8VPerformance Safety check sheet CVK-UB4 CVK-UB4I Control Panel Trial Operation Introduction Precautions for Safe Operation Unqualified personnel may cause electric shock or fire Components List Wiring ASS’Y Continuation of the tableNylon Clip 6N Assembling of the solenoid valve Installation of the door switch 㪪㪺㫉㪼㫎㩷㪜㩷Installation of the back-up kit Installation Wiring Control Panel Trial Operation TemperatureCalibration CVK-UB4 CVK-UB4I JK1659-150B
Related manuals
Manual 2 pages 16.28 Kb

MDF-C8V specifications

The Sanyo MDF-C8V is a versatile and reliable medical refrigerator designed to meet the needs of healthcare facilities, laboratories, and pharmacies. It boasts a range of advanced features and technologies that ensure precise temperature control and safety for sensitive biological materials, vaccines, and pharmaceuticals.

One of the standout features of the Sanyo MDF-C8V is its capability to maintain a consistent temperature range between 2°C to 8°C, which is critical for the preservation of temperature-sensitive items. The unit is equipped with a microprocessor-controlled system that offers accurate temperature regulation and facilitates programmable settings. This allows users to customize the temperature according to their specific requirements.

An advanced refrigeration system is at the heart of the MDF-C8V, providing highly efficient cooling performance while minimizing energy consumption. The use of eco-friendly refrigerants ensures compliance with environmental regulations, making it an environmentally responsible choice. The cabinet is designed with high-quality insulation that enhances energy efficiency and maintains stable internal conditions.

The Sanyo MDF-C8V features an easy-to-read digital display that provides real-time temperature readings, allowing for constant monitoring of internal conditions. Additionally, an audible and visual alarm system alerts users if the temperature deviates from the preset range, enhancing the safety of stored items. This feature is particularly important in medical settings where even minor temperature fluctuations can compromise the integrity of vaccines and other critical materials.

For added convenience, the MDF-C8V comes with adjustable shelves that can accommodate various sizes of storage containers, making it easier to organize and access stored items. The unit's interior is designed to facilitate easy cleaning, ensuring hygiene standards are maintained in healthcare environments.

Furthermore, the Sanyo MDF-C8V is built with a robust exterior that is resistant to scratches and impacts, ensuring durability in busy clinical settings. Its compact design allows for easy placement in limited spaces without sacrificing storage capacity.

In summary, the Sanyo MDF-C8V is a highly functional medical refrigerator that combines precise temperature control, energy efficiency, and user-friendly features. Its advanced technologies and robust design make it an ideal solution for healthcare facilities looking to protect valuable vaccines and medications.