Sanyo MDF-C8V service manual Precautions for Safe Operation

Page 79

PRECAUTIONS FOR SAFE OPERATION

It is imperative that the user complies with this manual as it contains important safety advice.

Items and procedures are described so that you can use this unit correctly and safely. If the precautions advised are followed, this will prevent possible injury to the user and any other person.

Precautions are illustrated in the following way:

WARNING

Failure to observe WARNING signs could result in a hazard to personnel possibly resulting in serious injury or death.

CAUTION

Failure to observe CAUTION signs could result in injury to personnel and damage to the unit and associated property.

Symbol shows;

this symbol means caution.

this symbol means an action is prohibited.

this symbol means an instruction must be followed.

Be sure to keep this manual in a place accessible to users of this unit.

< Label on the unit >

This mark is labeled on the cover in which the electrical components of high voltage are enclosed to prevent the electric shock.

The cover should be removed by a qualified engineer or a service personnel only.

WARNING

As with any equipment that uses CO2 gas, there is a likelihood of oxygen depletion in the vicinity of the equipment. It is important that you assess the work site to ensure there is suitable and sufficient ventilation. If restricted ventilation is suspected, then other methods of ensuring a safe environment must be considered. These may include atmosphere monitoring and warning devices.

3

76

Image 79
Contents MDF-C8V Effective models Contents Features ŶStructural specifications SpecificationsŶControl specifications ŶPerformance specifications %8 DimensionsRefrigeration circuit diagram 㪚㪐㩷 Refrigeration circuit welding pointsCooling unit parts Components on PCB Compressor terminals layout Electrical PartsSpecification of sensor Wiring diagram Circuit diagram CN3 Connection on PCBTemperature alarm Control specificationKey and Switch Temperature controlPV. Note Auto Return is not worked in F09 and F10 Other functionFunction mode F04 Purpose Simply passing through if entered by mistake Model code ‘003’ MDF-C8V Offset value Differential The point of compressor on and OFFWhen the power is supplied without battery Remote alarm terminalSensor failure Fan motor operation and compressor protection Other specificationsParts layout Electric BOX Lower back side 䇭㪥㫆䇭㫃㫆㪸㪻 Test Data䇭㪥㫆䇭㫃㫆㪸㪻 㪈㪈㪌㪭䇭㪍㪇㪟㫑䇭㪘㪫㪊㪌 䇭㪥㫆䇭㫃㫆㪸㪻 Collection and charge of refrigerant Page Page MDF-C8V Contents Introduction Precautions for Safe Operation Unqualified personnel may cause electric shock or fire Abnormal operation may cause electric shock or fire Precautions for Safe Operation Environmental Conditions Freezer Components Freezer Components Control panel Installation Site Fixing the unit InstallationAdjusting the leveling foot Removing the packaging materials and tapesSTART-UP of Unit Operation after power failureKEY Lock Function Chamber Temperature SettingAlarm Temperature Setting Alarm Temperature Setting Setting of Alarm Resume Time Change of Compressor Delay Time Remote Alarm Terminal Alarms and safety functions Alarms & Safety FunctionsCleaning of cabinet Routine MaintenanceDefrosting Battery Handling of battery Replacement of BatteryLocation of a nickel-metal-hydride battery Removal of nickel-metal-hydride batteryMalfunction Check/Remedy TroubleshootingDisposal of Unit Recycle of batteryGerman EnglishSpanish FrenchPortuguese ItalianSwedish DutchTemperature Recorder Option Installation of MTR-85H Temperature Recorder Option Installation of MTR-G85 Temperature Recorder Option BACK-UP System Option BACK-UP System Option MDF-C8V SpecificationsPerformance Safety check sheet CVK-UB4 CVK-UB4I Control Panel Trial Operation Introduction Precautions for Safe Operation Unqualified personnel may cause electric shock or fire Components List Continuation of the table Wiring ASS’YNylon Clip 6N Assembling of the solenoid valve 㪪㪺㫉㪼㫎㩷㪜㩷 Installation of the door switchInstallation of the back-up kit Installation Wiring Control Panel Trial Operation TemperatureCalibration CVK-UB4 CVK-UB4I JK1659-150B
Related manuals
Manual 2 pages 16.28 Kb

MDF-C8V specifications

The Sanyo MDF-C8V is a versatile and reliable medical refrigerator designed to meet the needs of healthcare facilities, laboratories, and pharmacies. It boasts a range of advanced features and technologies that ensure precise temperature control and safety for sensitive biological materials, vaccines, and pharmaceuticals.

One of the standout features of the Sanyo MDF-C8V is its capability to maintain a consistent temperature range between 2°C to 8°C, which is critical for the preservation of temperature-sensitive items. The unit is equipped with a microprocessor-controlled system that offers accurate temperature regulation and facilitates programmable settings. This allows users to customize the temperature according to their specific requirements.

An advanced refrigeration system is at the heart of the MDF-C8V, providing highly efficient cooling performance while minimizing energy consumption. The use of eco-friendly refrigerants ensures compliance with environmental regulations, making it an environmentally responsible choice. The cabinet is designed with high-quality insulation that enhances energy efficiency and maintains stable internal conditions.

The Sanyo MDF-C8V features an easy-to-read digital display that provides real-time temperature readings, allowing for constant monitoring of internal conditions. Additionally, an audible and visual alarm system alerts users if the temperature deviates from the preset range, enhancing the safety of stored items. This feature is particularly important in medical settings where even minor temperature fluctuations can compromise the integrity of vaccines and other critical materials.

For added convenience, the MDF-C8V comes with adjustable shelves that can accommodate various sizes of storage containers, making it easier to organize and access stored items. The unit's interior is designed to facilitate easy cleaning, ensuring hygiene standards are maintained in healthcare environments.

Furthermore, the Sanyo MDF-C8V is built with a robust exterior that is resistant to scratches and impacts, ensuring durability in busy clinical settings. Its compact design allows for easy placement in limited spaces without sacrificing storage capacity.

In summary, the Sanyo MDF-C8V is a highly functional medical refrigerator that combines precise temperature control, energy efficiency, and user-friendly features. Its advanced technologies and robust design make it an ideal solution for healthcare facilities looking to protect valuable vaccines and medications.