KS-342
2.Turn the power on (up), and then turn the oscillator switch on (down).
3.To monitor both channels together, set the monitoring selection switch to the L/R setting (for an explanation of the monitoring switch settings).
4.Adjust the level of the outputs so that the meter reads 0 dB (or the equivalent, depending on the meter.
5.Remember to turn the oscillator off when the adjustment has been made.
The center position is off.
Master level controls Adjust the output level with these con- trols. These are recessed to avoid accidental changes to the output level in normal operation.
Monitor selection, level and headphone jack Select the signals monitored through the headphones using the monitor selection control. AUX selects the auxiliary signals, L selects the left, and R selects the right output bus, L/R is stereo and L+R is a mono combination of the left and right busses. Note that these assignments change in MS mode, as explained below.
Use the level control to set the monitoring level as heard through the headphones, plugged into the standard 1⁄4" stereo jack. Power switch and indicator Turn the unit on by pushing the switch up. The indicator lights green when the internal batteries are used, and orange when an external power supply is used. It flashes when the battery level becomes low. When it flashes, you should replace the batteries.
COMP indicator Lights when the compressor is in operation, as switched from the side panel.
NOTE
The compressors use battery power. Turn the compressors off when you do not need them to extend the life of your batteries.
SLATE button Push to activate the slate function with the in- ternal microphone.
Meters There are three different types of meter available with the
14