GENERAL INSTALLATION INSTRUCTIONS

Ensure gas supply and gas type, as shown on unit nameplate agree.

Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1-1996, the National Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2 as applicable and in accordance with local codes.

Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level the unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs mounted, lift if necessary to move unit.

Pipe threading compound must be resistant to the action of liquefied petroleum gases.

Caution: DO NOT use an op n flame to check for leaks. Check all gas pipi g for leaks with soap and water solution before operat ng unit.

THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY. Noncombustible clearan es:

0" sides (0 mm)

0" rear (0 mm)

Do not obstruct he fl w f combus ion and ventilat on air, under the unit by the legs or b ind the unit by the flue.

Adequate cle ra ce for air openings o the combustion chamber is r

ired. Do not pl ce objects

between the bottom of the unit d he coun er op.

 

There mu be adequate clearance f removable hru he fr nt if the gas l

r r m val of the front panel. All maj r parts exc pt the burners are is di c nnected.

CANADIAN NSTALLATION MUST COMPLY WITH THE CANADIAN ELECTRICAL CODE, CSA C22.2 AS APPLICABLE.

!

!

European Community Installation Instructions:

“THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON. IN THE UK, CORGI REGISTERED INSTALLERS (INCLUDING THE REGIONS OF BRITISH GAS) UNDERTAKE TO WORK TO SAFE AND SATISFACTORY STANDARDS. THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS AND THE RELEVANT BUILDING REGULATIONS / I REGULATIONS. DETAILED RECOMMENDATIONS ARE CONTAINED IN THE FOLLOWING BRITISH STANDARD CODES OF PRACTICE - BS 6172, BS 5440 PART 2, BS 6891"

"THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE RULES IN FORCE”

"MUST BE INSTALLED IN A WELL VENTILATED AREA. Ventilation requirements ie. B.S. 5440.”

IMPORTANT:

We strongly recommend having a competent professional install this equipment. Such a person should be familiar with local gas regulations. A gas company representative should approve the completed installation.

Image 5
Contents Important for Future Reference Rating InstructionsWarni G a fact GAS PressureSafety Precautions Table of ContentsImmediately Inspect for Shipping Damage Specifications and DimensionsEuropean Community Installation Instructions General Installation InstructionsOperating Instructions Lighting InstructionsInitial Cleaning CleaningCleaning Cleaning Burner Air S UttersService Repair MaintenanceOver Night Shutdown Extended Shutdown 4 Days or LongerProblem Troubleshooting Guide16 23 52 48 Description Quan GF-15H & GF-15HLP Parts ListGF-30H & GF-30HLP Exploded Assembly View GF-30H & GF-30HLP Parts List Meat DoughnutsMiscellaneous Poultry