Lincoln 1450, 1451 Manifold Pressure Adjustment, Temperature Regulation Valve Replacement

Page 10

6.Remove incoming nipple.

7.Remove pilot tube assembly from control valve.

8.Disconnect pipe union just above solenoid valve.

9.Disconnect wiring from control valve making note of wire numbers and location. Remove piping from old valve for installation on new valve.

10.Reassemble in reverse order - after assembly is complete, be sure to check manifold pressure

(3.5" W.C. NAT GAS 10" W.C. LP) and adjust if necessary. (See Section "MANIFOLD PRESSURE -

ADJUSTMENT")

NOTE: Check all gas line fittings for leaks after installation.

PILOT

LINE CONNECTION

MANIFOLD ADJUSTMENT

SCREW LOCATED UNDER

COVER SCREW

FRONT VIEW

MANIFOLD PRESSURE

ADJUSTMENT CONNECTION

MANIFOLD ADJUSTMENT

SCREW LOCATED UNDER

COVER SCREW

TOP VIEW

MANIFOLD PRESSURE - ADJUSTMENT

1.Remove control panel top and front cover.

2.WITH ELECTRIC POWER AND GAS OFF: Remove the outlet pressure tap plug from the gas control valve and install the adapter fitting and manometer.

3.Turn on electric power and gas and start-up oven.

4.With oven at full fire, manifold pressure should be (3.5" W.C. NAT/ 10" W.C. LP). If adjustment is needed, remove cover screw from valve body and adjust by turning regulator screw. (C.W. to increase, C.C.W. to decrease).

5.Turn off electric power and gas, replace cover screw, remove manometer and adapter; Replace pressure tap plug.

6.Check pressure tap for gas leaks before closing panel.

7.Close control panel and check system operation.

TEMPERATURE REGULATION VALVE - REPLACEMENT

1.Shut off power at main breaker.

2.Shut off gas supply.

3.Remove control panel top and front cover.

4.Remove gas control valve (See "GAS CONTROL VALVE")

5.Disconnect wires from temperature regulation valve.

6.Remove two (2) hex nuts that hold main orifice bracket in place.

7.Remove temperature regulation valve assembly.

8.Remove piping from temperature regulation valve.

9.Reassemble in reverse order.

10.Check all fittings for leaks.

10

Impinger I – 1450 Series Service Manual - Domestic

Image 10
Contents Impinger Conveyor Ovens NAT. GAS LP GASSchematic Diagram Troubleshooting Guide Symptom Possible Cause EvaluationNot running, check for opens, shorts or grounds With Power on and Thermocouple Belt JAM Cooling FAN, Control BOX Replacement FAN, Main ReplacementCAPACITOR, Motor Replacement FAN Spider FAN HUB ConeTo Remove the Blower Wheel for Periodic Cleaning THERMOSTAT, Cooling FAN ReplacementBurner Blower Motor Replacement Burner Control ReplacementManifold Pressure Adjustment AdjustmentTemperature Regulation Valve Replacement Thermocouple Measurment Temperature Millvolts Approx Burner Ignitor ReplacementThermocouple Replacement Burner Control Transformer ReplacementON-OFF Switch Replacement Main Orifice ReplacementPilot Orifice Replacement Oven Control ReplacementThis page intentionally left blank General View Advantage Series Letter Part Number DescriptionPage N28654 and Above Letter DescriptionPage Oven Back Advantage Series GAS and Electric Page Conveyor 1450 Series Page This page intentionally left blank This page intentionally left blank