Lincoln 1450 Reversing Conveyor Direction, Main Orifice Replacement, Pilot Orifice Replacement

Page 12

REVERSING CONVEYOR DIRECTION

All ovens leaving our plant are wired to operate conveyors from left to right. To reverse conveyor direction, use the following procedure.

1.Shut off power at oven switch.

2.Set conveyor reversing switch in the other position.

3.Turn oven “on” and check for proper operation.

MAIN ORIFICE - REPLACEMENT

1.Shut off power at main breaker.

2.Remove control panel top and front panel.

3.Remove gas control valve assy.

4.Remove two (2) nuts from burner orifice bracket.

5.Disconnect pipe union.

6.Remove assembly and replace main orifice.

7.Reassemble in reverse order and check system operation. NOTE: Check all gas line fittings for leaks.

PILOT ORIFICE - REPLACEMENT

1.Shut off power at main breaker.

2.Shut off gas supply.

3.Remove burner assembly (See "Burner Assembly").

4.Remove pilot line from pilot orifice.

5.Remove pilot orifice from burner ignitor.

6.Reassemble in reverse order. NOTE: Check all gas line fittings for leaks.

ON-OFF SWITCH - REPLACEMENT

1.Shut off power at main breaker.

2.Remove control box cover.

3.Remove access cover.

4.Depress spring clips on side of switch and push out.

5.Remove wires from back of switch, note wire number and location.

6.Reassemble in reverse order and check system operation.

NOTE: Make sure switch housing is fully seated in control box housing.

OVEN CONTROL – REPLACEMENT

A.Shut off power at main breaker.

B.Remove control box cover and front panel.

C.Remove all wiring connections and mark for reassembly.

D.Remove oven control by pulling control from the mounting pins. Remove control from oven.

E.Before installing new oven control, set voltage jumper (located at the bottom center of the oven control) to the proper voltage (120V/240V) position. Install the four pushbutton extensions (included with the oven control) by pushing the extensions onto the four set buttons on control.

F.Reassemble in reverse order and check system operation.

G.Set the oven control for the proper operating mode. The 1400 series ovens use a single temperature control system. The oven control must be set to the proper operating mode. Set the control as follows: With the oven power switch “off”, depress the “time” and “up” buttons and turn the oven “on”. Control will indicate “Imp I or Imp II” Release the buttons, The control will indicate “Temp to store”. Press the “up” or “down” button until “Imp I” appears on the display. Press the “temp” button. The control is now set for single burner operation.

FUSE HOLDER – REPLACEMENT

1.Shut off power at main breaker.

2.Remove control box cover.

3.Remove all wiring from fuse holder and mark for reassembly.

4.Remove mounting nut for fuse holder and remove fuse holder.

5.Reassemble in reverse order and check system operation.

12

Impinger I – 1450 Series Service Manual - Domestic

Image 12
Contents Impinger Conveyor Ovens NAT. GAS LP GASSchematic Diagram Troubleshooting Guide Symptom Possible Cause EvaluationNot running, check for opens, shorts or grounds With Power on and Thermocouple Belt JAM FAN, Main Replacement CAPACITOR, Motor ReplacementCooling FAN, Control BOX Replacement FAN Spider FAN HUB ConeTHERMOSTAT, Cooling FAN Replacement Burner Blower Motor ReplacementTo Remove the Blower Wheel for Periodic Cleaning Burner Control ReplacementAdjustment Manifold Pressure AdjustmentTemperature Regulation Valve Replacement Burner Ignitor Replacement Thermocouple ReplacementThermocouple Measurment Temperature Millvolts Approx Burner Control Transformer ReplacementMain Orifice Replacement Pilot Orifice ReplacementON-OFF Switch Replacement Oven Control ReplacementThis page intentionally left blank General View Advantage Series Letter Part Number DescriptionPage N28654 and Above Letter DescriptionPage Oven Back Advantage Series GAS and Electric Page Conveyor 1450 Series Page This page intentionally left blank This page intentionally left blank