Lincoln 1400, 1200, 1000 service manual Dip Switch, Switch Replacement FAN, HEAT, Conveyor

Page 54

Dip Switch

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

TYPE I

OFF

OFF

OFF

ON

OFF

OFF

 

 

 

 

TYPE II

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

TYPE III

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

NOTE: When on 50 HZ power, dip switch #2 must be "ON"

 

 

 

 

With power ON turn time and temperature cal. pot. fully counterclockwise.

 

 

 

Display should read: (Wait 15-20 seconds)

 

 

 

 

 

 

TYPE I 9:30 + 10 sec.475 + 10°F

 

 

 

 

 

 

 

TYPE II 9:20 + 10 sec. HHH

 

 

 

 

 

 

 

TYPE III

9:35 + 10 sec. 635 + 10°F

 

 

 

 

 

 

 

Turn time and temp. cal. pot. fully clockwise.

 

 

 

 

 

 

Display should read: (Wait 15-20 seconds)

 

 

 

 

 

 

TYPE I 10:20 + 10 sec.

615 + 10°F

 

 

 

 

 

 

 

TYPE II 10:10 + 10 sec.

475 + 10°F

 

 

 

 

 

 

 

TYPE III

10:20 + 10 sec.

475 + 10°F

 

 

 

 

 

 

 

Turn time pot. to 10:00 minutes and temp. pot. to 540°F. Time reading 10:00 ± 5 seconds.

Temperature reading should be steady at 540°F + 10°F. If these readings are not achieved, replace display.

NOTE: After simulator test is completed, the oven Time/Temperature Display must be re-calibrated.

SWITCH REPLACEMENT (FAN, HEAT, CONVEYOR)

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Remove switch access cover.

4.Depress the spring clips on the sides of the switch and push out.

5.Remove wires from back of switch. Note wire number and location.

6.Install new switch in reverse order and check.

SWITCH REPLACEMENT - (FAN SWITCH UPDATE)

INSTALLATION OF DOUBLE POLE FAN SWITCH #369260 IN PLACE OF SINGLE POLE FAN SWITCH #350705

NOTE:

This change is not necessary for proper operation of oven nor is it

 

permissible to change under warranty. Should be changed only at

 

customer's request and their agreement to pay your bill.

ADVANTAGE:

Allows time/temp. display, in older models, to operate same as current

 

production models. Also allows locked time/temp. display (caused by

 

voltage surge, interruption or spike) to be reset by fan switch rather than

 

circuit breaker.

IDENTIFICATION:

To determine which fan switch you have, observe if temperature displays

 

stays on during cooling down. If it stays on , you have the single pole

 

switch. If it goes out as soon as fan switch is turned off you have the double

 

pole switch.

REPLACEMENT:

Replace single pole switch # 350705.

 

Install double pole switch # 369260.

 

Disconnect lead indicated by # in proper diagram and reroute as shown.

 

Install jumper lead indicated by * in proper diagram.

 

Reapply all other leads as removed.

54

Impinger I -–1000 Series Service Manual - Domestic

Image 54
Contents Impinger Conveyor Ovens Table of Contents Model 1204 120/230 VAC 60HZ Natural GAS/DUAL Belt Power SupplyModel 1200 120/230 VAC 60HZ Natural GAS/DUAL Belt Control BOX AutoHeat Circuit TemperatureTime Temp Display ControlConveyor Drive TIME/TEMP DisplayModel 1240 120/230 VAC 60HZ Natural GAS/DUAL Belt TIME/TEMP Time Temp Display Schematic / 1000 Schematic / 1004 Schematic / 1022, 1023 S/N Q19077 & below Schematic / 1022, 1023 S/N Q19078 & Above Schematic / 1040, 1041 S/N Q14279 & below Schematic / 1040, 1041 S/N Q14280 & Above Schematic / 1200 Schematic / 1202, 1203 S/N Q14790 & below Schematic / 1202, 1203 S/N Q14791 & Above Schematic / 1204 Schematic / 1240, 1241 S/N Q14279 & below Schematic / 1240, 1241 S/N Q14280 & Above Troubleshooting Guide 1000 Symptom Possible Cause EvaluationGAS Ovens Ignition Control For ovens withJohnson Controls Honeywell IgnitionControl Mechanical Temperature ControlFlameFor ovens with ThermostatCode Troubleshooting Guide Electric Ovens Model Series 1000Page Page Page Page Page Page CAPACITOR, Motor REMOVAL, Installation & AdjustmentsMOTOR, Main FAN FAN, MainFAN Spider FAN HUB Cone Cool Down SwitchAbove GAS Above Electric RELAY, D.P.S.TTHERMOSTAT, Cooling FAN Burner Blower MotorTo Remove the Blower Wheel for Periodic Cleaning AIR Pressure SwitchBlower WHEEL, Burner Burner Assembly Manifold PRESSURE-ADJUSTMENTGAS Control Valve Temperature Control Board Manifold Pressure AdjustmentTemperature Control Valve Robert Shaw Solenoid ValveThermocouple Measurement Chart Temperature Control Potentiometer ReplacementTHERMOCOUPLE- Replacement Mercury ContactorHeating Element Ignition Control24V GND Transformer 120/24 VAC Flame SensorBurner Ignitor Burner Light 24 VAC GAS OvensMain Orifice Burner Conveyor Motor Replacement Bodine SNPilot Orifice Burner Potentiometer Conveyor Speed ControlConveyor Motor Replacement Baldor 1000 Series SN 4390 Series SN 4390Coupling and Encoder Disc Conveyor Motor Control Board Optical Encoder AssemblyTACH. Generator Motor Control Board CalibrationREG MIN MAX Motor Control Board Style 1 Control Board AdjustmentStyle 2 and Style 3 Control Board Adjustment StyleStyle DIP Switches Control Switch Position OFF BEARING, Conveyor Reversing Conveyor DirectionMini Circuit Breaker Drive ENDTRANSFORMER-STEPPER Motor Control Hall Effect Sensor ReplacementSN 2164 and Above OLD StyleOven Temperature Temperature Gauge ReplacementThermistor Replacement TRANSFORMER, TIME/TEMP. DisplaySwitch Settings ALL 1000 & 1200 Series OvensType OFF SWITCH, DISPLAY, SET Bottom of Time Temp DisplayDip Switch Switch Replacement FAN, HEAT, ConveyorSwitch Replacement FAN Switch Update GAS Valve Replacement and Adjustments Spark Generator Replacement Ignition Control ReplacementHigh Limit Thermostat Replacement Solenoid Valve ReplacementIgniter Sensor Assembly Replacement Burner Alarm Light ReplacementPilot Light 220V Replacement Burner Blower Motor ReplacementRELAY, GAS Control Replacement Model 1046,1047 Relay ASSEMBLY, Burner Blower Motor ReplacementTemperature Control Replacement Time Delay RELAY, 20 Minute ReplacementThis page intentionally left blank Parts / Model Series 1000 & 1200 General Letter DescriptionBlow UP / 1000, 1200 General Parts / Access Door & 1050 Door Blow UP / Access Door & 1050 Door Parts / Model 1000,1001,1050,1051,1004, &1005 S/N 100 to Blow UP / 1000, 1001, 1050, 1051, 1004, & 1005 S/N 100 to Parts / Model 1000,1001,1004, and 1005 S/N 4390 & Above Blow UP 1000, 1001, 1004, 1005 S/N 4390 & Above Parts Blow UP / 1022 369247 Shaft Lock Ring Blow UP / 1040 Parts / 1200, 1201, 1204 Blow UP / 1200, 1201, 1204 Parts Blow UP / 1202 Electronic Temperature Control Blow UP / 1240 Parts / Oven Back GAS Blow UP / Oven Back GAS Parts / Oven BACK- Electric Blow UP / Oven Back Electric Parts / Conveyor Motor Assembly S/N 4390 & Above Blow UP / Conveyor Motor Assembly S/N 4390 & Above Parts / Series 1000 Conveyor Blow UP / Series 1000 Conveyor Parts / Series 1200 Conveyor Control SeeBlow UP / Series 1200 Conveyor Control Parts / Series 1200 Conveyor Blow UP / Series 1200 Conveyor This page intentionally left blank This page intentionally left blank
Related manuals
Manual 20 pages 1.12 Kb Manual 92 pages 51.22 Kb

1000, 1200, 1400 specifications

The Lincoln series, particularly the models Lincoln 1000, 1200, and 1400, represents an evolution in luxury vehicles, combining elegance with cutting-edge technology. Each model builds upon its predecessor while introducing features that enhance performance, comfort, and safety.

Starting with the Lincoln 1000, this model set the foundation for the series. It showcased a refined design characterized by sleek lines and an impressive presence on the road. The Lincoln 1000 was equipped with a powerful engine, delivering smooth acceleration and a quiet ride. Interior features included premium materials such as leather upholstery, real wood accents, and a state-of-the-art sound system. Additionally, it offered advanced climate control systems, ensuring passenger comfort. Safety features were also prioritized, with multiple airbags and stability control systems included to enhance driver confidence.

Moving on to the Lincoln 1200, this model took luxury to the next level. The exterior design was more aggressive, with a revised grille and enhanced aerodynamics for better fuel efficiency. The engine options expanded, offering hybrid technology for environmentally conscious consumers without sacrificing power. Inside, the Lincoln 1200 featured an upgraded infotainment system, incorporating a larger touchscreen display along with smartphone integration for connectivity on the go. This model also introduced adaptive cruise control and lane-keeping assist, showcasing Lincoln’s commitment to safety and innovation.

The Lincoln 1400 represents the pinnacle of this series. This model incorporates all the advancements of the previous iterations while introducing next-generation technologies. A hybrid powertrain with electric capabilities provides a quieter, more efficient drive. The design includes sophisticated lighting technology, such as adaptive LED headlights that adjust to road conditions. Inside, the cabin has been transformed into a haven of luxury, with customizable ambient lighting, heated and ventilated seats, and an advanced noise cancellation system for a serene driving experience. Furthermore, the Lincoln 1400 emphasizes driver assistance technology, featuring an array of sensors and cameras to support features like automatic parking and enhanced collision prevention systems.

In conclusion, the Lincoln 1000, 1200, and 1400 models showcase a remarkable journey of luxury and technology, with each iteration bringing forth innovative features and design enhancements that elevate the driving experience. As Lincoln continues to evolve, the commitment to craftsmanship, comfort, and cutting-edge technology remains central to its identity.