Product Dimensions

30" (76.2 cm) Model

A

B

C

Cabinet Dimensions

IMPORTANT: If installing a range hood or microwave hood combination above the cooktop, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.

A

D

CB

M

K E

FG

H

D

 

 

E

 

 

A. 30" (76.2 cm) - gas on glass

C. 3¹³⁄₁₆" (9.7 cm)

29½"

(74.9 cm) - gas on metal

D. 5¼" (13.3 cm)

B. 21½"

(54.6 cm)

E. 12¼" (31.1 cm)

36" (91.4 cm) Model

A

B

C

D

A. 36" (91.4 cm)

E

D. 5¼" (13.3 cm)

B. 21" (53.3 cm)

E. 15¼" (38.7 cm)

C. 3¹³⁄₁₆" (9.7 cm)

 

LJ

JI

A. 30" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models

B. Combustible area above countertop (shown by dashed box above)

C. 30" (76.2 cm) minimum clearance between top of cooktop platform and bottom of uncovered wood or metal cabinet

(24" [61 cm] minimum clearance if bottom of wood or metal cabinet is covered by not less than ¹⁄₄" [0.6 cm] flame retardant millboard covered with not less than No. 28

MSG sheet steel, 0.015" [0.04 cm] stainless steel, or

0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper) D. 13" (33 cm) recommended upper cabinet depth

E. 1³⁄₁₆" (3.1 cm)

F. 19¹⁵⁄₁₆" (50.6 cm)

G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop within minimum horizontal clearances to cooktop

H. Grounded outlet - Locate within 24" (61 cm) of right rear corner of cutout (with no undercounter built-in oven installed below cooktop)

I. 28½" (72.4 cm) on 30" models; 34½" (87.6 cm) on 36" models

J. 6" (15.2 cm) minimum distance to nearest left and right side combustible surface

K. 2⁷⁄₈" (7.3 cm) minimum distance to rear combustible surface

L. Gas line opening - Wall: Anywhere 6" (15.2 cm) below underside of countertop. Cabinet floor: anywhere within 6" (15.2 cm) of rear wall is recommended (with no undercounter built-in oven installed below cooktop)

M. 24" (61.0 cm) minimum countertop depth is required

NOTES: After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the cooktop base. To avoid this modification, use a base cabinet with sidewalls wider than the cutout.

If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the countertop to the top of the drawer (or other obstruction) in base cabinet is required. The drawer depth may need to be shortened to avoid interfering with the regulator.

IMPORTANT: If an undercounter built-in wall oven is to be installed below this cooktop, the grounded outlet (H) and gas supply piping must be located in an adjacent cabinet.

This cooktop and its gas and electrical supply sources must be installed before the undercounter built-in wall oven is installed.

4

Image 4
Contents Installation Instructions Cooktop Safety Your safety and the safety of others are very importantTools and Parts Installation RequirementsLocation Requirements Product Dimensions Cabinet Dimensions30 76.2 cm Model 36 91.4 cm ModelElectrical Requirements Gas Supply RequirementsType of Gas Gas Supply LineInstall Cooktop Installation InstructionsMake Gas Connection Complete Connection Wall oven installed below cooktopNo appliance below cooktop Complete Installation If the low flame needs to be adjustedCheck Flame Height Check Operation of Surface BurnersSécurité DE LA Table DE Cuisson Votre sécurité et celle des autres est très importanteExigences demplacement Exigences DinstallationOutillage et pièces Dimensions du produit Dimensions du placardModèle de 30 76,2 cm Modèle de 36 91,4 cmSpécifications électriques Spécifications de lalimentation en gazType de gaz Gaz naturelCanalisation de gaz Détendeur de gazCaractéristiques dalimentation du brûleur Test de pressurisation de la canalisation de gazInstructions Dinstallation Installation de la table de cuissonRaccordement au gaz Raccordement typique par raccord flexibleCompléter le raccordement Sachet de pièces. Aligner les encoches des chapeaux deAchever linstallation Contrôle du fonctionnement des brûleurs de surfaceVérification de la taille des flammes Si les brûleurs ne sallument pas correctement