Bunn H5X service manual Service, Component Access

Page 12

SERVICE

This section provides procedures for testing and replacing various major components used in this dispenser should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem.

Component Access

WARNING – Disconnect the dispenser from the power source before the removal of any panel or the replace- ment of any component.

P1770

P1770

The limit thermostat, liquid level probe, tank heater, and temperature sensor are located at the top of the dispenser. Access is gained by removing the top lid, attached with three 4-40 slotted-head screws.

NOTE - Completely drain the tank before tipping the dispenser.

WARNING – Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. Disconnect the dispenser from the power source when servicing, except when electrical tests are required and the test procedure specifically states to connect the dispenser to the power source.

The check valve, electronic control board, safety overflow switch, solenoid valve, overflow tube tempera- ture sensor and terminal block are located at the rear of the dispenser. Access is gained by removing the upper and lower rear panels. The upper is attached with six 8-32 slotted-head screws. The lower is attached with four 8-32 slotted-head screws. The middle panel must not be removed from the dispenser.

P1770

Electronic Controls

10

Limit Thermostat

17

Safety Overflow Switch

18

Solenoid Valve

19

Tank Heater

20

Electronic Control Board Troubleshooting: Check these items first

Is circuit board popped-out of bracket?

Is circuit board wet due to misaligned overflow tube?

Is water in overflow cup activating float switch?

Is overflow cup not making good contact with tank?

Is dispenser being operated with panels re- moved?

12

10420.1 040309

 

Image 12 Contents
H5E, H5X BUNN-O-MATIC Commercial Product Warranty Contents IntroductionUser Notices Electrical Requirements CE RequirementsElectrical Hook-Up Plumbing Requirements Initial SET-UPPlumbing Hook-Up Programming Level 1 ProgrammingRestoring Factory Defaults Level 2 Programming Cleaning Wall Mounted Installation Draining the Dispenser Support for Large ReceptaclesTroubleshooting Problem Probable Cause RemedyFlashes Equipment will not Operate Safety overflow switch Water boils continuously Temperature control Service Component AccessService Electronic Controls LocationLiquid Level Control Test Procedure H5X Thermostat Wiring Connections Service Limit Thermostat Test ProcedureService Safety Overflow Switch Safety Overflow SwitchService Solenoid Valve Solenoid ValveService Tank Heater Tank HeaterSchematic Wiring Diagram H5E Schematic Wiring Diagram H5X Volts AC RED Schematic Wiring Diagram H5XA, H5EA