Bunn H5X service manual Service Tank Heater

Page 20

SERVICE (cont.)

Tank Heater

Location:

The tank heater is located in the tank lid.

FIG. 9 TANK HEATER

P4093

 

Test Procedure:

1.Disconnect the dispenser from the power source.

2.Check the voltage across the terminals of the tank heater with a voltmeter. Connect the dispenser to the power source. The indication must be:

a.) 100 to 120 volts ac for 100 to 120 volt models or

b.) 200 to 240 volts ac for 200 to 240 volt models or

c.) 230 volts ac for 230 volt models.

3.Disconnect the dispenser from the power source.

If voltage is present as described, proceed to #4.

If voltage is not present as described, replace the tank heater.

4.Remove the tank heater from the tank lid and inspect it for cracks in the sheath.

If the sheath shows no sign of damage, proceed to #5.

If the sheath is damaged, replace the tank heater.

5.Check for continuity across the tank heater termi- nals.

If continuity is present as described, reinstall the tank heater. The tank heater is operating properly.

If continuity is not present as described, replace the tank heater.

Removal and Replacement:

1.Remove the wires to the tank heater.

2.Remove the 8-32 nuts from the tank heater flange.

3.Remove the tank heater.

4.Inspect the tank heater gasket and replace if neces- sary.

5.Securely install the new tank heater. Be certain of a watertight seal.

6.Reconnect the wires, FIG. 10.

BLU to Control

BLK to Limit

Board Relay

Thermostat

 

P1780

FIG. 10 TANK HEATER WIRING

20

10420.1 040309

 

Image 20
Contents H5E, H5X BUNN-O-MATIC Commercial Product Warranty User Notices ContentsIntroduction Electrical Hook-Up Electrical RequirementsCE Requirements Plumbing Hook-Up Plumbing RequirementsInitial SET-UP Programming Level 1 ProgrammingRestoring Factory Defaults Level 2 ProgrammingCleaning Wall Mounted InstallationDraining the Dispenser Support for Large ReceptaclesFlashes TroubleshootingProblem Probable Cause Remedy Equipment will not Operate Safety overflow switch Water boils continuously Temperature control Service Component AccessService Electronic Controls LocationLiquid Level Control Test Procedure H5X Thermostat Wiring Connections Service Limit Thermostat Test ProcedureService Safety Overflow Switch Safety Overflow SwitchService Solenoid Valve Solenoid ValveService Tank Heater Tank HeaterSchematic Wiring Diagram H5E Schematic Wiring Diagram H5X Volts AC RED Schematic Wiring Diagram H5XA, H5EA
Related manuals
Manual 9 pages 10.17 Kb Manual 2 pages 44.15 Kb Manual 25 pages 51 Kb Manual 24 pages 29.7 Kb

H5X specifications

The Bunn H5E and H5X coffee machines represent a leap forward in brewing technology, specifically tailored for commercial use. Both models focus on delivering high-quality coffee while maximizing efficiency, making them ideal choices for busy cafés and restaurants.

The Bunn H5E features a unique 5-liter dual tank system, which allows for faster brewing times and reduces wait periods for customers. This dual tank setup facilitates the simultaneous preparation of multiple coffee types, catering to a diverse clientele. The H5X, on the other hand, is equipped with advanced electronic controls that permit precise temperature adjustments to ensure that the ideal brewing conditions are maintained, enhancing flavor extraction.

One of the standout features of both models is the patented BrewOptimized Technology. This technology helps maintain optimal water temperature and consistent flow rates throughout the brewing process, ensuring that each cup of coffee meets the high standards expected in commercial settings. Additionally, the units utilize a patented stainless steel brew basket that enhances durability and simplifies cleaning, making maintenance less of a chore for busy staff.

Another significant characteristic of the H5E and H5X is their programmable settings, which allow operators to customize brewing parameters according to their specific preferences or customer needs. This flexibility means that establishments can experiment with various coffee profiles, ensuring that they serve only the best products to their patrons.

Safety is also a priority in the design of these machines. The H5E and H5X come equipped with built-in safety features such as automatic shut-off and thermal overload protection, which help to prevent accidents and enhance longevity. Moreover, their compact design allows for easy installation in a variety of settings, whether it's a small coffee stand or a large restaurant operation.

Both the Bunn H5E and H5X models are energy-efficient, with features that minimize power consumption without compromising performance. This focus on sustainability not only helps reduce overhead costs but also appeals to environmentally conscious consumers.

In summary, the Bunn H5E and H5X coffee machines are engineered for high performance, reliability, and versatility. With features designed to provide quick, quality coffee while ensuring ease of operation and maintenance, these machines are ideal for any establishment that takes its coffee seriously. Whether you’re brewing for a crowd or crafting specialty drinks, the H5E and H5X stand ready to deliver excellent results every time.