Bunn HC-2 HC-3 service manual Solenoid Valve Inlet, Tank Heater

Page 33

SERVICE (cont.)

SOLENOID VALVE (INLET) (cont.)

If continuity is not present as described, replace the solenoid valve.

6.Check the solenoid valve for coil action. Connect the dispenser to the power source. Listen care- fully in the vicinity of the solenoid valve for a "clicking" sound as the coil magnet attracts.

7.Disconnect the dispenser from the power source.

If the sound is heard as described and water will not pass through the solenoid valve, there may be a block- age in the water line before the solenoid valve or, the solenoid valve may require inspection for wear, and removal of waterborne particles.

If the sound is not heard as described, replace the solenoid valve.

Removal and Replacement:

1.Remove the white and violet wires from the so- lenoid valve.

2.Turn-off the water supply to the dispenser.

3.Disconnect the water lines to and from the sole- noid valve.

4.Remove the two #10-32 screws and nuts secur- ing the solenoid to the rear panel. Remove sole- noid.

5.Using two #10-32 screws and nuts install new solenoid valve on rear panel.

6.Securely fasten the water lines to and from the solenoid valve.

7.Refer to Fig. 28 when reconnecting the wires.

WHI from Terminal

Block

VIO from Liquid

Level Board

P1217

FIG. 28 INLET SOLENOID VALVE TERMINALS

TANK HEATER

FIG. 29 TANK HEATER

P1199.40

 

Location:

 

The tank heater is located inside the tank and secured to the tank lid.

Test Procedure:

1.Disconnect the dispenser from the power source.

2.Check the voltage across the black and white wires 120 volt models or black and red wires for 120/208 volt models or 120/240 volt models with a voltme- ter. Connect the dispenser to the power source. The indication must be:

a)120 volts ac for two wire 120 volt models;

b)208 volts ac for three wire 120/208 volt models.

c)240 volts ac for three wire 120/240 volt models and two wire 240 volt models.

3.Disconnect the dispenser from the power source.

If voltage is present as described, proceed to #4.

If voltage is not present as described, refer to the dispenser wiring diagram and check the wiring har- ness.

4.Disconnect the black wire and the white or red wire from the tank heater terminals.

33

27591 031597

 

Image 33
Contents Serial # HC00025000 UP BUNNHC-2Introduction WarrantyUser Notices 12368.000227620.0000 Electrical Requirements Initial SET-UPElectrical HOOK-UP Plumbing RequirementsAdjustments CleaningDispenser USE Cold Beverage SET-UP OptionalTroubleshooting Draining the HOT Water TankHopper Dispense Rate of Product Problem Probable Cause Remedy TroubleshootingProblem Dripping from dispense tip Lime build-up Problem Probable CauseOn stainless steel surfaces can Ing in serious leaksTesting procedure. See Weak product Water temperature30 or Tip with a thermometerProbable Cause Remedy Troubleshooting ProblemComponent Access ServiceContents Auger Drive ComponentsIf voltage is present as described, proceed to #5 Auger Drive ComponentsWasher Auger Motor Locknut Dust Seal Shoulder Screw Hopper AssyRight HC-2 ServiceTest Procedure BallastLocation Control Thermostat Remove temperature probe from the tankLocation Mechanical Thermostat Electronic Thermostat OptionalThermostat Terminals Control ThermostatDispense Switch Dispense SwitchFAN Test ProceduresSteam Collector #6-32 Screw Mixing Chamber Frother and Whipper MotorRing Pull the mixing chamber 2 out of the whipper chamberWhipper Motor Terminals Frother and Whipper MotorReconnect the eight pin connector to the hopper delay board Hopper Delay BoardDisconnect the wires from the switch termi- nals HOT/COLD Switch OptionalLamp Replacement Refer to Fig Lamp HolderDoor Assy Service Level Control Board and Probe Level Control Board and Level ProbeLimit Thermostat Level Board TerminalsOverflow Protection Switch Overflow Protection SwitchRUN/RINSE Switch RUN/RINSE SwitchCold Water Solenoid Valve Solenoid Valve Cold Water OptionalSolenoid Valves Dispense Cold Water Solenoid TerminalsSolenoid Valves Dispense Disconnect the water line from the solenoid valveSolenoid Valve Inlet Tank Heater Solenoid Valve InletRefer to when reconnecting the wires to the tank heater Tank Heater SwitchTank Heater Tank Heater Switch Terminals Tank Heater SwitchMODELSONLYcont Transformer 240V TWO WireSchematic Wiring Diagram HC-2, & HC-3 Schematic Wiring Diagram HCA-2, & HCA-3

HC-2 HC-3 specifications

The Bunn HC-2 and HC-3 are high-performance commercial coffee brewers designed for cafes, restaurants, and institutions that prioritize quality, efficiency, and reliability. Renowned for their exceptional brewing capabilities, both models come with a range of features that cater to the demanding needs of coffee enthusiasts and professionals alike.

One of the core characteristics of the Bunn HC-2 and HC-3 is their brewing technology. These machines utilize a patented steeping mechanism that allows for optimal water temperature and contact time, extracting the finest flavors from the coffee grounds. The precise temperature control, maintained at a consistent level, ensures that every cup of coffee is brewed to perfection. Furthermore, the machines have an impressive brew capacity, with the HC-2 capable of brewing up to 3.8 gallons per hour, while the HC-3 can brew up to 5.3 gallons per hour, making them ideal for high-traffic environments.

Another significant feature of the Bunn HC-2 and HC-3 is their ease of use. The user-friendly interface allows baristas to quickly set brew cycles and adjust brewing parameters to suit different coffee types. Both models are designed with a sleek, ergonomic aesthetic that fits seamlessly into any workspace, while also being built with durable materials to withstand the rigors of daily use.

In terms of efficiency, these brewers come equipped with energy-saving technology. The automatic warmers on both machines adjust the heat output based on the coffee’s temperature, reducing energy consumption without compromising quality. Additionally, the compact design of these units means they occupy minimal counter space, making them suitable for both small and large establishments.

Maintenance is straightforward with the Bunn HC-2 and HC-3, as they feature a self-diagnostic system that alerts users to any potential issues. This feature minimizes downtime and ensures the longevity of the equipment. Furthermore, the brewing components can be easily accessed for cleaning and maintenance.

In summary, the Bunn HC-2 and HC-3 stand out in the commercial coffee brewing market with their advanced brewing technology, high capacity, user-friendly design, energy efficiency, and ease of maintenance. These features make them a preferred choice for anyone looking to deliver high-quality coffee consistently, ensuring that businesses can satisfy even the most discerning coffee drinkers. With Bunn’s commitment to innovation and quality, these brewers continue to set the standard in the coffee equipment industry.