Bunn H5E, DV manual H5X Thermostat

Page 10

Electronic Controls (cont.)

7.Reconnect the pink wire to terminal 5 of the elec- tronic control assembly.

8.Loosen the compression fitting, remove the probe from the tank lid, and inspect it for mineral depos- its. Replace it if necessary. Keep the exposed ends of the probe away from any metal surface of the dispenser.

9.Check the voltage across terminals 1 & 4 of the elec- tronic control assembly with a voltmeter. Connect the dispenser to the power source. The indication must be:

a.) 100 to 120 volts ac for 100 to 120 volt models or

b.) 200 to 240 volts ac for 200 to 240 volt models or

c.) 230 volts ac for 230 volt models after a delay of approximately 5 seconds.

10.Touch the screw head end of the probe to the dis- penser housing. The indication must be 0.

11.Move the probe away from the dispenser housing. The indication must again be:

a.) 100 to 120 volts ac for 100 to 120 volt models or

b.) 200 to 240 volts ac for 200 to 240 volt models or

c.) 230 volts ac for 230 volt models after a delay of approximately 5 seconds.

12.Disconnect the dispenser from the power source.

Temperature Control Flow Charts (cont.)

If voltage was present as described, reinstall the probe, the sensing function of the system is operating properly.

H5X THERMOSTAT

PROBLEM: Boils Excessively - Fills Cup

If voltage was not present as described, check the pink probe wire and the green ground wire for continuity and/or replace the probe.

Temperature Control Test Procedure

1.Disconnect the dispenser from the power source.

2.Check the voltage across terminals 3 & 4 of the electronic control circuit board with a voltmeter. Connect the dispenser to the power source.The indication must be:

a.) 100 to 120 volts ac for 100 to 120 volt models or

b.) 200 to 240 volts ac for 200 to 240 volt models or

c.) 230 volts ac for 230 volt models.

3.Disconnect the dispenser from the power source.

4.Check the voltage across the tank heater terminals with a voltmeter. Connect the dispenser to the power source. The indication must be:

a.) 100 to 120 volts ac for 100 to 120 volt models or

b.) 200 to 240 volts ac for 200 to 240 volt models or

c.) 230 volts ac for 230 volt models.

5.Disconnect the dispenser from the power source.

H5E THERMOSTAT

PROBLEM: Boils

Drain cup

Retry

Red Light On While

Yes

Boiling

 

?

 

 

No

 

 

 

 

 

 

Replace Steam Sensor

Drain cup

Retry

Red Light On While

Yes

Boiling

 

?

 

 

No

 

 

 

Replace Control Assembly

Disconnect Blue Wire From

Control Board Pin 7

Retry

Still Boiling

?

No

Finished

Yes

Replace Control Assembly

Disconnect Blue Wire From

Control Board Pin 7

Retry

Still Boiling

Yes

?

 

 

No

 

 

 

 

 

 

Replace Triac Assembly

Check For Split

Tank Heater

Still Boiling

Yes

?

 

 

No

 

 

 

 

 

 

Replace Triac Assembly

Check For Split

Tank Heater

Replace Control Board

Replace Control Board

10

42311 071310

 

Image 10
Contents H5E/DV PC Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Contents 19-23Problem Probable Cause Remedy FlashesProblem Probable Cause Lime build-up Water boils continuously Temperature controlNoises Water supply Ready indicator will not light Deposits. Delime as requiredComponent Access H5E/DV-PC/X Component Access H10XElectronic Controls Liquid Level Control Flow ChartsLocation Liquid Level Control Test Procedure Service Electronic ControlsService H5X Thermostat Replace the electronic control board Test Procedure Service Limit ThermostatLocation Limit thermostat is located on the tank lid Service Safety Overflow Switch Safety Overflow WiringService Solenoid Valve Late Models If voltage was present as described, proceed to #5Service Solenoid Valve Early Models Location Tank heater is located in the tank lid Service Tank HeaterCheck for continuity across the tank heater termi- nals Service Steam Sensor Thermistor Thermistor PositionService Dispense Valve PC Only Location Dispense Valve is located behind control panelSingle Phase 230V AC 2 Wire + GND Wire + GND Schematic Wiring Diagram H5E/H5X Wire + GND Single Phase