SERVICE

WARNING – Disconnect the dispenser from the power source before the removal of any panel or the replacement of any component. WARNING - Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. Disconnect the dispenser fromthe power source when servicing, except when electrical tests are required and the test procedure specifically states to connect the dispenser to the power source.

Component Access - H5E/DV-PC/X

P1770.30

The check valve, electronic control assembly, safety overflow switch, solenoid valve, overflow tube tempera- ture sensor and terminal block are located at the rear of the dispenser. Access is gained by removing the upper and lower rear panels. The upper is attached with six 8-32 slotted-head screws. The lower is attached with four 8-32 slotted-head screws. The middle panel must not be removed from the dispenser.

Component Access - H10X

:$51,1*



9HU\+RW:DWHU

8VH:LWK&DUH

P878.30

The check valve, electronic control assembly, over- flow protection switch, solenoid valve, overflow tube temperature sensor, triac assembly (EARLY MODELS ONLY) and terminal block are located on the side of the dispenser. Access is gained by removing the side panel. The panel is attached with eight 8-32 slotted- head screws.

Faceplate Removal - H5 ELEMENT: After removing top cover, remove the two upper screws securing the faceplate. Carefully lift faceplate straight up until the three lower screws clear the key holes.

7

42311 022311

 

Image 7
Contents Phone 217 529-6601 FAX 217 H5E/DV PCBUNN-O-MATIC Commercial Product Warranty 19-23 ContentsFlashes Problem Probable Cause RemedyProblem Probable Cause Deposits. Delime as required Water boils continuously Temperature controlNoises Water supply Ready indicator will not light Lime build-upComponent Access H10X Component Access H5E/DV-PC/XElectronic Controls Liquid Level Control Flow ChartsLocation Liquid Level Control Test Procedure Service Electronic ControlsService H5X Thermostat Replace the electronic control board Test Procedure Service Limit ThermostatLocation Limit thermostat is located on the tank lid Safety Overflow Wiring Service Safety Overflow SwitchIf voltage was present as described, proceed to #5 Service Solenoid Valve Late ModelsService Solenoid Valve Early Models Location Tank heater is located in the tank lid Service Tank HeaterCheck for continuity across the tank heater termi- nals Thermistor Position Service Steam Sensor ThermistorLocation Dispense Valve is located behind control panel Service Dispense Valve PC OnlySingle Phase 230V AC 2 Wire + GND Wire + GND Schematic Wiring Diagram H5E/H5X Wire + GND Single Phase
Related manuals
Manual 25 pages 51 Kb Manual 9 pages 10.17 Kb Manual 2 pages 44.15 Kb Manual 25 pages 6.43 Kb

DV, H5E, H5X specifications

The Bunn H5E and H5X coffee machines represent a leap forward in brewing technology, specifically tailored for commercial use. Both models focus on delivering high-quality coffee while maximizing efficiency, making them ideal choices for busy cafés and restaurants.

The Bunn H5E features a unique 5-liter dual tank system, which allows for faster brewing times and reduces wait periods for customers. This dual tank setup facilitates the simultaneous preparation of multiple coffee types, catering to a diverse clientele. The H5X, on the other hand, is equipped with advanced electronic controls that permit precise temperature adjustments to ensure that the ideal brewing conditions are maintained, enhancing flavor extraction.

One of the standout features of both models is the patented BrewOptimized Technology. This technology helps maintain optimal water temperature and consistent flow rates throughout the brewing process, ensuring that each cup of coffee meets the high standards expected in commercial settings. Additionally, the units utilize a patented stainless steel brew basket that enhances durability and simplifies cleaning, making maintenance less of a chore for busy staff.

Another significant characteristic of the H5E and H5X is their programmable settings, which allow operators to customize brewing parameters according to their specific preferences or customer needs. This flexibility means that establishments can experiment with various coffee profiles, ensuring that they serve only the best products to their patrons.

Safety is also a priority in the design of these machines. The H5E and H5X come equipped with built-in safety features such as automatic shut-off and thermal overload protection, which help to prevent accidents and enhance longevity. Moreover, their compact design allows for easy installation in a variety of settings, whether it's a small coffee stand or a large restaurant operation.

Both the Bunn H5E and H5X models are energy-efficient, with features that minimize power consumption without compromising performance. This focus on sustainability not only helps reduce overhead costs but also appeals to environmentally conscious consumers.

In summary, the Bunn H5E and H5X coffee machines are engineered for high performance, reliability, and versatility. With features designed to provide quick, quality coffee while ensuring ease of operation and maintenance, these machines are ideal for any establishment that takes its coffee seriously. Whether you’re brewing for a crowd or crafting specialty drinks, the H5E and H5X stand ready to deliver excellent results every time.