TROUBLESHOOTING (cont.)
PROBLEM
Spitting or excessive steaming
PROBABLE CAUSE
1. Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
REMEDY
Inspect tank assembly for excessive lime deposits. Delime as required.
2. Control Thermostat
| 1. Funnel Tip |
Refer to Service - Control Thermo- stat for testing procedures. See page 20
The brew funnel should be cleaned thoroughly before each brew cycle to lessen the chance of tea leaf par- ticles clogging the
Dripping from sprayhead | 1. | Syphon System |
| 2. | Lime |
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for ex- cessive lime deposits. Delime as required.
3. Brew Solenoid Valve
Water flows into tank continuously | 1. Brew Timer |
(ON/OFF or Slector Switch "ON") |
|
Water flows into tank continuously | 1. Brew Solenoid Valve |
(ON/OFF or Selector Switch "OFF") |
|
Refer to Service - Brew Solenoid Valve for testing procedures. See page 15
Refer to Service - Brew Timer for testing procedures. See page 17 or 18
Refer to Service - Brew Solenoid Valve for testing procedures. See page 15
Page 11 | 10145 | 072600 |
|
|