Bunn T3A, T6A Spitting or excessive steaming, Control Thermostat Drip-out time too long

Page 11

TROUBLESHOOTING (cont.)

PROBLEM

Spitting or excessive steaming

PROBABLE CAUSE

1. Lime Build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate corrosive reactions resulting in serious leaks.

REMEDY

Inspect tank assembly for excessive lime deposits. Delime as required.

2. Control Thermostat

Drip-out time too long

1. Funnel Tip

Refer to Service - Control Thermo- stat for testing procedures. See page 20

The brew funnel should be cleaned thoroughly before each brew cycle to lessen the chance of tea leaf par- ticles clogging the drip-out tip.

Dripping from sprayhead

1.

Syphon System

 

2.

Lime Build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate corrosive reactions resulting in serious leaks.

The brewer must be level or slightly lower in front to syphon properly.

Inspect the tank assembly for ex- cessive lime deposits. Delime as required.

3. Brew Solenoid Valve

Water flows into tank continuously

1. Brew Timer

(ON/OFF or Slector Switch "ON")

 

Water flows into tank continuously

1. Brew Solenoid Valve

(ON/OFF or Selector Switch "OFF")

 

Refer to Service - Brew Solenoid Valve for testing procedures. See page 15

Refer to Service - Brew Timer for testing procedures. See page 17 or 18

Refer to Service - Brew Solenoid Valve for testing procedures. See page 15

Page 11

10145

072600

 

 

Image 11
Contents Telephone 217 529-6601 FAX 217 Post Office BOX SPRINGFIELD, IllinoisIntroduction Warranty#00831.0000 #00656.0000 #03408.0000 #03409.0000 User NoticesElectrical Hook-Up Electrical RequirementsPlumbing Requirements Initial SET-UP Fill & Heat Initial Timer AdjustmentOperating Controls Adjusting Brew VolumesON/OFF Switch T3 only TEA Brewing CleaningSelector Switch T6 only Start Switch Remedy Troubleshooting Problem Probable Cause Brew cycle will not start Probable Cause Remedy TroubleshootingProblem Dilution cycle will not start Dilution Solenoid Valve Problem Probable Cause RemedyDripping from sprayhead Spitting or excessive steamingControl Thermostat Drip-out time too long Beverage overflows dispenser Weak beverage Plumbing Lines Water Supply Tank Heater Dry tea leaves remain in the funnelBrewer is making unusal noises Contents ServiceComponent Access Brew Solenoid Valve ServiceSolenoid Valve Terminals Service Brew Solenoid ValveIf continuity is not present as described, refer to Brew TimerIndication must be If voltage is present as described, proceed to #4If voltage is as described, proceed to #7 Service Digital Brew Timer Late ModelsDigital Timer Wiring Service Digital Brew Timer Late ModelscontControl Thermostat Dilution Solenoid Valves Test Procedure Disconnect the brewer from the power sourceSource. The indication must be Dilution TimerClockwise With a voltmeter, check the voltage across Limit ThermostatON/OFF or Selector Switch WHI/VIO On left or right positionStart Switch Tank Heater 10145 072600 10145 072600 10145 072600