Elkay EDFP210FPC, EDFP217FPC, EDFP214FPC dimensions EDFP217FP ROUGH-IN Drawings

Page 5

EDFP217FP

ROUGH-IN DRAWINGS

FIG. 4

PAGE 5

FINISHED FLOOR

97565C

1.

Wall should already be framed for the fountains using dimensions shown in Fig. 3. Shown dimensions pertain to installation location.

 

These dimensions are required for compliance with ANSI Standard A117.1. and ADA (Framing shown for reference only).

 

 

2. Remove bottom covers from fountains and save the screws.

 

 

3.

Install the fountains using bolts and washers (not provided). Tighten securely.

(Rev.J

4.

Attach drain tubes to fountains and cut to required length using the freeze resistant boxes as guides.

5.

Install freeze-resistant boxes - see box instructions.

-

6.

Replace bottom covers.

8/07)

 

 

 

 

 

 

EDFP210FP*B EDFP214FP*B EDFP217FP*B

Image 5
Contents IMPORTANT! Installer Please Note Installation/Care/Use ManualEDFP210FP/EDFP214FP Mounting Bolt and Access Hole Layout EDFP210FP/EDFP214FP ROUGH-IN Drawings EDFP217FP Mounting Bolt and Access Hole Layout EDFP217FP ROUGH-IN Drawings EDFP210FP*B EDFP214FP*B EDFP217FP*B Cable Sheath Adjustment Operation of Quick Connect Fittings Parts List