Elkay EDFP214FPC, EDFP217FPC, EDFP210FPC dimensions Operation of Quick Connect Fittings

Page 7

EDFP210FP*B EDFP214FP*B EDFP217FP*B

The freeze resistant package must be mounted on an interior wall in a heated area. The room temperature of the interior heated area must be 50° F (10° C) or higher. The freeze resistant package may be surface or recessed mounted. If recess mounted the surface of the cover must be flush with the interior wall surface. The package is furnished with screws for mounting the cover to the box. If the box is recess mounted, do not fasten the top and bottom of the cover to the box. Use the holes on the front only.

1.Assemble the operating cable to the fountain bracket. (Fountain should be mounted to exterior wall) Create a loop in the cable and thread the free end of the cable through the wall into the freeze resistant box. The adjustment nuts should be in the middle of threaded area on the operating cable. See Figure 9

2.Connect free end of operating cable to the valve-operating bracket. The end of the cables must be recessed into the indents on the pivot brackets.

3.Remove cable free play by adjusting the jam nuts on the ends of the operating cable. See Figure 6

4.Connect water line from fountain bubbler into freeze resistant box. The connection to the box uses a quick connect water fitting. Position the water line, in the fountain, to drain back into interior mounted box. Any water left standing, in the exterior line, can freeze.

To insert tubing, push tube straight into fitting until it reaches a positive stop. To remove tubing from the fittings, relieve water pressure, push in on dark gray collar while pulling out on the tubing. See Figure 11

5.Connect drain and water supply lines to the freeze resistant fountain. Refer to Figure 1 for component positions. Inline strainer must be used on the inlet water line.

Start-up

1.Turn on building water supply and check all connections for leaks. Repair as required.

2.Stream height is factory set at 35 PSI. If stream height needs to be changed adjust the regulator in the freeze resistant package. Clockwise adjustment raises stream height, counter clockwise adjustment will lower stream.

3.Adjust operating cable as required. Cable system should have a minimal amount of free play to allow for proper valve operation. If the system is too tight the valve will stay in the on position creating constant water flow. Too much free play will result in non-operation of the valve with the push-buttons.

4.Note: Water from the drain back tube in the freeze resistant package, will continue to run while the valve is actuated.

5.After cable system is adjusted properly stuff flexible insulation into any openings between the outside wall and the interior box.

6.Recheck all connections. If all connections are leak free replace cover(s) on the freeze resistant box(es) and fountain(s).

 

3/8" O.D. UNPLATED

 

1/4" O.D. TUBE

COPPER TUBE CONNECT

 

COLD WATER SUPPLY

BUILDING WATER

WATER INLET

 

 

INLET

 

 

NOTE: WATER FLOW DIRECTION

SERVICE STOP

(NOT FURNISHED)

 

FIG. 10

OPERATION OF QUICK CONNECT FITTINGS

 

SIMPLY PUSH IN

TUBE IS

PUSH IN COLLET

 

TUBE TO ATTACH

SECURED

TO RELEASE TUBE

 

 

IN POSITION

 

 

 

 

PUSHING TUBE IN BEFORE

 

 

 

PULLING IT OUT HELPS TO

 

FIG. 11

 

RELEASE TUBE

 

 

97565C (Rev. J - 8/07)

 

PAGE 7

 

 

Image 7
Contents IMPORTANT! Installer Please Note Installation/Care/Use ManualEDFP210FP/EDFP214FP Mounting Bolt and Access Hole Layout EDFP210FP/EDFP214FP ROUGH-IN Drawings EDFP217FP Mounting Bolt and Access Hole Layout EDFP217FP ROUGH-IN Drawings EDFP210FP*B EDFP214FP*B EDFP217FP*B Cable Sheath Adjustment Operation of Quick Connect Fittings Parts List