CDA RC9301 manual Provison for ventilation

Page 28

Provison for ventilation

The appliance should be installed into a room or space with an air supply in accor- dance with BS 5440-2: 2000.

For rooms with a volume of less than 5 m3 - permanent ventilation of 100 cm2 free area will be required.

For rooms with a volume of between 5 m3 and 10 m3 a permanent ventilation of 50 cm2 free area will be required unless the room has a door which opens directly to the outside air in which case no permanent ventilation is required.

For rooms with a volume greater than 10 m3 - no permanent ventilation is required.

NB. Regardless of room size, all rooms containing the appliance must have direct access to the outside air via an openable window or equivalent.

Where there are other fuel burning appliances in the same room, BS 5440-2: 2000 should be consulted to determine the correct amount of free area ventilation require- ments.

The above requirements allow also for use of a gas oven and grill but if there are other gas burning appliances in the same room, consult a qualified engineer.

28

Image 28
Contents RC9301 Single Cavity Gas Cooker CDA Contents Introduction Assembling the backguardFeatures and technical data Gas burnersMinute counter Control panelMinute counter Hob burners How to use the hob burnersLighting of the hob burners Choice of burner Burners Pan diameterCorrect use of triple-ring burner How to use the gas oven Lighting the oven gas burnerOven ThermostatOven cooking temperatures How to use the gas grill Lighting the grill gas burnerOven light Important WarningRotisserie Use of the rotisserieDo’s and do not’s Do’s and do not’sImportant notes For your safetyOven door guard Care and maintenance Cleaning the hobFlexible tube Gas tapsEnamelled parts Changing the oven lightBurners Triple ring burnerRemoval of the inner glass door panel Storage compartmentAssembling and dismantling of the side runner frames Inside of ovenOven floor Door assembly Removing the oven doorFor Installer Location Fitting the adjustable feet Levelling the cooker Stability bracket Provison for ventilation Gas installation Important NoteInstallation to Natural Gas Gas connectionPlug 200 mm 700 mm Injectors replacement of top burners Conversion to Natural Gas or to LPGAdjusting of the minimum of the top burners Table for the choice of the injectors Cat II 2H3+Replacement of the oven burner injector Replacement of the grill burner injector Primary air of the oven burner Primary air of the grill burnerLubrication of the gas taps Regulating of the oven minimumElectrical installation For your safety please read the following informationElectrical feeder cable connection Feeder cable section type H05RRFAppliance servicing Guarantee Limit of CoverRC 9301 .. cookers