CDA RC9301 manual Gas connection, Installation to Natural Gas

Page 30

Gas connection

The installation of the gas appliance to Natural Gas or LP Gas must be carried out by a suitably qualified and registered installer. Installers shall take due account of the provi- sions of the relevant British Standards Code of Practice, the Gas Safety Regulations and the Building Standards (Scotland)(Consolidation) Regulations issued by the Scottish Development Department.

Installation to Natural Gas

Installation to Natural Gas must conform to the Code of Practice, etc. The supply pressure for Natural Gas is 20 mbar.

The installation must conform to the relevant British Standards.

Installation to LP Gas

When operating on Butane gas a supply pressure of 28-30 mbar is required. When using Propane gas a supply pressure of 37 mbar is required.

The installation must conform to the relevant British Standards.

Warning: Only a suitably qualified and registered installer, also with technical knowl- edge of electricity should install the appliance. He should observe the Regulations and Codes of Practice governing such installation of gas appliances.

Note: It is recommended that the gas connection to the appliance is installed with a flexible connecting tube made to BS5386.

Notes:

Flexible hoses can be used where the sited ambient temperature of the hose does not exceed 70°C. These hoses must be manufactured in accordance with BS669 part 1 and be of the correct construction for the type of gas being used.

Gas hoses designed for natural gas MUST NOT be used for supplying LPG gas (LPG gas hoses can be identified by a either a red band or stripe on the rubber outer coating of the hose).

The hose should not be crushed or trapped or be in contact with sharp or abrasive edges.

Using a suitable leak detection fluid solution (e.g. Rocol) check each gas connection one at a time by brushing the solution over the connection.

The presence of bubbles will indicate a leak.

If there is a leak, tighten the fitting and then recheck for leaks.

IMPORTANT!

Do not use a naked flame to test for leaks.

30

Image 30
Contents RC9301 Single Cavity Gas Cooker CDA Contents Introduction Assembling the backguardFeatures and technical data Gas burnersControl panel Minute counterMinute counter How to use the hob burners Hob burnersLighting of the hob burners Choice of burner Burners Pan diameterCorrect use of triple-ring burner Oven How to use the gas ovenLighting the oven gas burner ThermostatOven cooking temperatures How to use the gas grill Lighting the grill gas burnerOven light Important WarningRotisserie Use of the rotisserieDo’s and do not’s Do’s and do not’sFor your safety Important notesOven door guard Flexible tube Care and maintenanceCleaning the hob Gas tapsEnamelled parts Changing the oven lightBurners Triple ring burnerRemoval of the inner glass door panel Storage compartmentInside of oven Assembling and dismantling of the side runner framesOven floor Door assembly Removing the oven doorFor Installer Location Fitting the adjustable feet Levelling the cooker Stability bracket Provison for ventilation Gas installation Important NoteInstallation to Natural Gas Gas connectionPlug 200 mm 700 mm Injectors replacement of top burners Conversion to Natural Gas or to LPGAdjusting of the minimum of the top burners Table for the choice of the injectors Cat II 2H3+Replacement of the oven burner injector Replacement of the grill burner injector Primary air of the oven burner Primary air of the grill burnerLubrication of the gas taps Regulating of the oven minimumElectrical installation For your safety please read the following informationElectrical feeder cable connection Feeder cable section type H05RRFAppliance servicing Guarantee Limit of CoverRC 9301 .. cookers

RC9301 specifications

The CDA RC9301 is a compact and efficient refrigerator designed to meet the demands of modern households. It combines innovative technology with user-friendly features, ensuring optimal performance in food preservation and energy efficiency.

One of the standout features of the CDA RC9301 is its A+ energy rating. This classification indicates a high level of energy efficiency, which can help reduce electricity costs and environmental impact. With a capacity of 178 liters, the refrigerator provides ample space for grocery storage while maintaining a sleek and stylish design that fits seamlessly into any kitchen decor.

The appliance features an adjustable thermostat, allowing users to easily set the preferred temperature for their food items. This level of control is essential for maintaining the freshness of perishable goods. In addition, the CDA RC9301 is equipped with a reversible door, providing flexibility in installation. Homeowners can configure the refrigerator to suit their kitchen layout, ensuring convenient access and optimal space utilization.

The RC9301 also employs advanced cooling technology, which maintains a consistent internal temperature throughout the refrigerator, minimizing fluctuations that can negatively affect food quality. The frost-free operation eliminates the need for manual defrosting, saving users time and effort in kitchen maintenance.

Moreover, the refrigerator features interior LED lighting, which not only enhances visibility but is also more energy-efficient compared to traditional lighting solutions. The clear shelving provides an organized layout, making it easy to locate items and maximize storage capacity.

With a quiet operation, the CDA RC9301 ensures minimal disruption in the home environment, making it suitable for open-plan living spaces. User-friendly controls and a clean, modern design further enhance its appeal, making it a practical addition to any kitchen.

Overall, the CDA RC9301 is an excellent choice for those seeking a reliable and energy-efficient refrigerator. Its combination of innovative features, ample storage space, and modern design makes it a valuable asset for any household, ensuring that food remains fresh and organized while complementing the aesthetic of the kitchen.