Haier HRF- 349AA, HRF- 329AA, HRF- 369AA service manual No Refrigerating

Page 22

Maintenance Service and Trouble Shooting

refrigerating effect is due to the accumulation of refrigerating oil left in the evaporator tubing in case no other troubles have been found . To clear off refrigerating oil left in the evaporator ,dismantle the evaporator ,purge it thoroughly and then dry it .In case it is difficult to dismantle it ,charge refrigerant from the evaporator inlet to wash it several times ,then purge and dry it with nitrogen .

7)Flowing obstructed in refrigerating system Analysis of Trouble

Because the refrigerating system was originally not purged

thoroughly ,some of the filter screen meshes have been clogged by dirt accumulated in the filter after using it for a certain time of period ,thus resulting in a decrease in flow rate ,and hence a poorer refrigerating effect .

The abnormal phenomena caused by this kind of slight clogging in the system are as follows: the gas discharge pressure is lower ,the temperature of discharged gas drops down ,the position clogged has a temperature lower than that in normal conditions ,and for a severe clogging ,even dew condensation as frosting may appear .

Remedy

Purge the tubing ,and after replacing the dry filter with a new one or clearing it thoroughly ,recharge the system with refrigerant and seal the charging port .

B.No Refrigerating

The phenomenon that the compressor runs normally ,but no frost (or only a little frost ) appears on the evaporator ,and the refrigerator temperature does not drop down is called “no refrigerating”. There are many causes for this trouble and it is relatively complicated , too . In servicing ,special attention to finding direct causes for this phenomenon .Three main potential causes for this trouble are analyzed below :

1)All refrigerant in the system has leaked out Analysis of Trouble

Leak points in the refrigerating system have not been found and

repaired timely ,thus resulting in the total escape of refrigerant .There are two kinds of leakage :I) slow leakage for instance ,when we want to use a refrigerator that has been put out of quite a long time ,we find the leakage of refrigerant ,or in the course of its operation ,we have found that the refrigerator is gradually becoming not so cold and finally no refrigerating cab be achieved ; ii) fast leakage in that case ,all the refrigerant will escape swiftly due to abrupt rupture of system tubing .

Symptoms of total leakage of refrigerant are mainly as follows : the compressor can be started easily (if there is no damage to the compressor parts) and its operating current becomes low ,its gas suction pressure is high and discharge pressure is lower ,the gas discharge tube feels rather cold ,no sound of gas eruption from the liquid in the evaporator can be

21

Image 22
Contents Refrigerator ModelsContent Product code illumination and Series Introduction Specifications ModelsSafety precautions Safety precautions Safety precautions Parts and Functions Function Schedule System Flow Chart Schematic diagram of System Flow ChartProgram Diagram Start Read T TTs Stop =NmaxMaintenance Service and Trouble Shooting No coolingCompressor doesn’t stop YESCooling capacity is insufficient YESCompressor doesn’t work Normal Phenomena-Not Troubles for Refrigerators Look Common Troubles in Refrigerators and Their RemediesListen 3Touch and Feel Analysis of Troubles and Troubleshooting Maintenance Service and Trouble Shooting Maintenance Service and Trouble Shooting No Refrigerating Maintenance Service and Trouble Shooting Troubles of Compressor Stoppage due to electric troubles Maintenance Service and Trouble Shooting Maintenance Service and Trouble Shooting Occur generally. Remedy Analysis of Trouble Stronger vibration and loader noise Maintenance Service and Trouble Shooting