WARNING, continued

This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be properly supervised around this appliance.

Do not climb, stand, or hang on the appliance or door or allow children or animals to do so. Do not climb into the appliance or allow children or animals to do so. Death or serious injury could occur or the appliance could be damaged.

Be careful not to pinch fingers when opening and closing the door. Be careful when opening and closing the door when children are in the area.

Do not use combustible spray or place volatile or flammable substances near the appliance. They might catch fire.

Keep the area around the appliance clean. Dirt, dust, or insects in the appliance could cause harm to individuals or damage to the appliance.

NOTICE

Protect the floor when moving the appliance to prevent damage to the floor.

Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction. Do not place anything on top of the appliance. Blockage of airflow could negatively affect performance and damage the equipment.

Do not tightly pack the cabinet. Allow some space between items to ensure good air flow. Also allow space between items and interior surfaces.

Do not store items near the air outlet. They might freeze up and crack or break.

To prevent deformation or cracks, do not spray insecticide onto the plastic parts or let them come into contact with oil.

To avoid damage to the gasket, use only the door handle when opening and closing.

6

Image 6
Contents HR24A Hoshizaki AMERICA, INC Contents Page Important Safety Information Page Specifications Electrical and Refrigerant Data Storage Capacity and DimensionsStorage Capacity Dimensions Unit mmII. General Information Construction HR24ASequence of Operation Sequence Cycles and ShutdownCool Down Restart EvapFM and Defrost icons are onHR24A Sequence Flow Chart Sequence Flow ChartControl Board and Display Module Control Board Layout Display Module LayoutCabinet Temperature Default SettingsDisplay Module Icons Control Panel LockoutAlarm Safeties High and Low Temperature Alarm Values AH or ALService Menu Service Menu AccessService Menu Chart Page AL alarm sensor. Do not adjust Fan operation with door closed 247 Address not used Baud Rate not used Parity not used III. Technical Data Refrigeration Circuit Wiring Diagram IV. Service Diagnosis Diagnostic ProcedurePage Energy Saving Mode Control Board Check Startup and Cool DownDefrost Thermistor Check Diagnostic Chart Appliance Not CoolingEvaporator is Frozen Up Defrost Fails to Start or TerminateReplacement of Components Service for Refrigerant LinesRefrigerant Recovery Brazing Evacuation and Recharge R-134aImportant Notes for Component Replacement Door Reversal Cleaning MaintenanceVII. Preparing the Appliance for Periods of Non-Use VIII. Disposal
Related manuals
Manual 20 pages 19.87 Kb

HR24A specifications

The Hoshizaki HR24A is an advanced refrigeration unit designed to meet the cooling needs of commercial kitchens and food storage facilities. Known for its reliability and efficiency, this model showcases several innovative features that set it apart in the competitive market of commercial refrigeration.

One of the standout characteristics of the Hoshizaki HR24A is its robust construction. Built with a durable stainless steel exterior, it not only adds aesthetic appeal but also ensures longevity and resistance to corrosion and wear. The interior is designed for easy cleaning, with rounded corners that minimize the buildup of grime and food particles.

The HR24A offers an impressive storage capacity, making it ideal for establishments with high-volume food storage requirements. With a temperature range typically between 33°F and 38°F, the unit maintains optimal conditions for preserving perishables such as meats, dairy, and vegetables. This precision in temperature control is essential for maintaining food safety and quality.

One of the key technologies integrated into the Hoshizaki HR24A is its advanced refrigeration system. Utilizing a highly efficient compressor and a fan-assisted cooling feature, the unit ensures rapid temperature recovery even in busy kitchen environments. This is crucial during peak hours when door openings are frequent, as it helps maintain consistent internal temperatures.

Energy efficiency is another hallmark of the HR24A. It is designed with environmentally friendly refrigerants and complies with Energy Star standards, which can lead to significant cost savings over time through reduced electricity consumption. This commitment to environmental responsibility makes it an attractive option for eco-conscious businesses.

In terms of user-friendliness, the HR24A is equipped with digital controls and adjustable shelving, allowing for customized organization according to specific storage needs. The LED lighting inside the unit provides excellent visibility, making it easy to locate items quickly, which is particularly beneficial during busy service periods.

Overall, the Hoshizaki HR24A combines durability, efficiency, and functionality, making it an exceptional choice for anyone seeking a reliable refrigeration solution in a commercial kitchen setting. Whether used in restaurants, hotels, or catering businesses, its impressive features and state-of-the-art technology continue to meet the demanding requirements of the foodservice industry.