Hoshizaki JWE-2400CUA-R-25B, JWE-24000CUA-L-25B Removal and Replacement of Rinse Pump Motor

Page 57

4)Make sure the O-rings are in place, and attach the wash pump motors to the tank discharge outlets and suction inlets. Secure the connections with the bands.

5)Tighten the bracket mounting screws.

6)Fill the tank with water, then check for water leaks from the joints. If there is a water leak, check the connections, and retighten the bands. If there are no water leaks, drain the tank.

7)Connect the wiring. When finished, cover the connections with the original plastic sheet cover and secure with a nylon tie. Make sure the connections are situated so that water and condensation cannot reach the connections.

Note: Be careful not to mix up the wire colors. Miswiring will cause reversal of the pump motor, resulting in improper operation.

8)Replace the front panel.

9)Make a trial run, and check for water leaks.

Fan Motor

Bracket

Pump Plug

 

 

Band

 

 

O-Ring

Wash Pump Motor

 

Wash Pump Motor

(Lower Spray Arm)

Fan Motor

(Upper Spray Arm)

C. Removal and Replacement of Rinse Pump Motor

1)Use the “ON/OFF” button on the operation panel to turn off the unit, then turn off the dishwasher and booster tank power supplies. Lockout/Tagout to prevent the power supplies from being turned back on inadvertently.

2)Remove the front panel.

3)Use the booster tank drain hose to drain the booster tank. WARNING! To avoid possible burns, allow the rinse water temperature to fall below 104°F (40°C) before draining.

4)The rinse pump motor is located at the rear right side of the machine compartment (JWE-2400CUA-L-25B) or located behind the control box and at the rear left side of the machine compartment (JWE-2400CUA-R-25B).

5)Remove the fan motor in front of the rinse pump motor.

52

Image 57
Contents Model JWE-2400CUA-L-25B JWE-2400CUA-R-25B Hoshizaki AMERICA, INC Contents Page Serious injury Important Safety InformationProperty Indicates important information about the use and careDishwasher Side Booster Side AC Supply Voltage Right to Left Nameplate Rating JWE-2400CUA-L-25B Dimensions/ConnectionsJWE-2400CUA-R-25B Dishwasher II. General Information A. ConstructionTop View Booster TankBox Functions Sequence of OperationIncreasing Rinse Water Flow Rate Page Table Limit Switch Emergency Stop ButtonDrain Dishwasher Sequence Flow Chart JWE-2400CUA-25B Flow ChartChart Auto FillCycle Wash Cycle/Rinse Cycle Control Board Location Control Board and Operation BoardCN4 Control Board LayoutCN1 CN2 Control Board DiagramError Codes Service Menu and Error LogWater Temperature Lamps DisplayService Menu Access Conveyor Speed SwitchReady Lamp Wash LampItem and Details Setting Range Display Service Menu ChartTemperature Display Error CodesBuzzer Low Water Temperature Lock Function Continuous Wash ModeOperation Time Display Special ModesOFF III. Service Diagnosis Diagnostic ProcedureSwitch Open/Closed Display Mode Page Error Code Table Error CodesError Code Log Auto Fill Error A1 Error Code DetailsPage Booster Tank Auto Fill Error A2 Wash Tank Water Level Error A3 Page Page Wash Tank Thermistor Error H1, H2 Booster Tank Thermistor Error H3, H4 Eeprom Error H6 ROM/RAM Error H5Conveyor Overload or Table Limit Error 1 L1 Conveyor Overload or Table Limit Error 2 L2 Booster Tank Error b1 Booster Tank Water Level Safety Error b2 Unit Will Not Start Service Flow ChartsSee III.B. Error Codes Replace Dishes Not Clean Page Inadequate Rinse Dishwasher will not start wash/rinse cycle Dishwasher Will Not Start Wash/Rinse CycleWash Tank Water Boils No or Inadequate Detergent/Rinse Aid SupplyWash Tank Water Not Draining Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Thermistor Check IV. Removal and Replacement of Components Removal and Replacement of Wash Pump MotorsRemoval of Panels Removal and Replacement of Rinse Pump Motor Rinse Pump Motor Page Removal and Replacement of Gear Motor Removal and Replacement of Conveyor Removal and Replacement of Crankshaft Removal and Replacement of Thermistor Removal and Replacement of Control BoxControl Board Removal and Replacement of Control Board or Operation BoardOperation Board Removal and Replacement of Heater Removal and Replacement of Float Switch Removal and Replacement of Thermostat Cleaning and Maintenance Instructions Daily Maintenance Wash the curtains Silverware Rack Rail Ring Install the curtain L in the wash compartment Monthly Inspection Weekly MaintenanceHeater ExteriorShutdown Descaling As RequiredService Panel Hook VI. Operating Instructions Long Storage, Relocation, Disposal, TransferVII. Technical Information Water Circuit Wiring Diagram
Related manuals
Manual 61 pages 38.47 Kb

JWE-2400CUA-R-25B, JWE-24000CUA-L-25B specifications

The Hoshizaki JWE-2400CUA-R-25B and JWE-24000CUA-L-25B are advanced ice machines designed to meet the diverse needs of commercial establishments requiring high volumes of ice. These state-of-the-art units combine innovative technology with energy efficiency, making them ideal for restaurants, hotels, bars, and other hospitality settings.

One of the main features of the JWE-2400CUA-R-25B is its high production capacity. This model can produce up to 2,400 pounds of ice in a 24-hour period, ensuring a continuous supply for busy operations. Similarly, the JWE-24000CUA-L-25B boasts an impressive production rate, accommodating even larger establishments. Both machines deliver crescent-shaped ice, which is favored for its rapid cooling properties and ease of use in beverages.

Energy efficiency is a highlight of both models. They are designed with environmentally friendly refrigerants, aligning with modern sustainability practices. These machines also incorporate advanced heat-exchange systems that maximize energy savings while maintaining optimal ice production. As a result, operators can enjoy significant reductions in energy costs without compromising on performance.

Durability and reliability are essential characteristics of the Hoshizaki JWE series. Constructed with high-quality materials, these units feature stainless steel exteriors that resist corrosion and wear, ensuring long-term operation in demanding environments. Additionally, the ice-making components are built to endure frequent use, allowing for consistent ice output over time.

The technology integrated into the JWE-2400CUA-R-25B and JWE-24000CUA-L-25B includes user-friendly digital controls that simplify operation and monitoring. These controls help operators track production levels, ice thickness, and machine status, allowing for proactive maintenance and reducing downtime. Furthermore, routine cleaning and maintenance are made straightforward, contributing to enhanced hygiene and overall ice quality.

In conclusion, the Hoshizaki JWE-2400CUA-R-25B and JWE-24000CUA-L-25B ice machines present a perfect blend of high capacity, energy efficiency, and durability. Their advanced features and technologies make them a reliable choice for any business requiring dependable ice production. With their user-friendly controls and robust design, these machines stand out as top contenders in the commercial ice maker market.