Hoshizaki JWE-2400CUA-R-25B, JWE-24000CUA-L-25B Long Storage, Relocation, Disposal, Transfer

Page 77

F. Long Storage, Relocation, Disposal, Transfer

When preparing the unit for long storage, shut down and clean the unit according to sections A - E.

If something seems wrong when restarting the unit after long storage, turn off the power supply, and immediately contact an authorized Hoshizaki service company.

WARNING

1.When restarting the unit after long storage, contact an authorized Hoshizaki service company. To prevent electric shock, do not restart the unit by yourself.

2.In case of relocation, contact an authorized Hoshizaki service company. Improper installation may cause water leak, electric shock or fire.

3.When disposing of the unit, contact an authorized Hoshizaki service company. Leaving the unit may violate laws or cause an unexpected accident.

NOTICE

When selling or transferring this product, tape the instruction manual and the installation manual to the exterior to provide the new owner with information on safe and proper use of the product.

VI. Operating Instructions

Before loading dishes in the rack, be sure to remove any leftovers (ex. meat, fish, vegetables), chopsticks, toothpicks, sticks, straws, paper products and plastics from the dishes. They may clog the piping and wash pump, resulting in reduction of washing performance or pump failure.

Install the separator and tank filters without creating a large gap at the tank overlap. Do not bang the tank filters and separator to clean or drain, or they may be deformed. Leftovers and other foreign matter may enter the tank and clog the piping and wash pump, resulting in reduction of washing performance or pump failure.

Insert the drain pipe (overflow pipe) after installing the separator. The separator may rise up to create a large gap at the tank overlap. Leftovers and other foreign matter may enter the tank and clog the piping and wash pump, resulting in reduction of washing performance or pump failure.

After closing time, always clean the tank filters, wash/rinse spray arms and water level sensor. When disassembling the spray arms, check and remove any leftovers clogging the pipe joints. Otherwise the leftovers may become hard to remove or spoil.

Read the instruction manual carefully to ensure safe and proper operation.

72

Image 77
Contents Model JWE-2400CUA-L-25B JWE-2400CUA-R-25B Hoshizaki AMERICA, INC Contents Page Serious injury Important Safety InformationProperty Indicates important information about the use and careDishwasher Side Booster Side AC Supply Voltage Right to Left Nameplate Rating JWE-2400CUA-L-25B Dimensions/ConnectionsJWE-2400CUA-R-25B Dishwasher II. General Information A. ConstructionTop View Booster TankBox Increasing Rinse Water Flow Rate FunctionsSequence of Operation Page Drain Table Limit SwitchEmergency Stop Button Dishwasher Sequence Flow Chart JWE-2400CUA-25B Flow ChartCycle ChartAuto Fill Wash Cycle/Rinse Cycle Control Board Location Control Board and Operation BoardCN4 Control Board LayoutCN1 CN2 Control Board DiagramError Codes Service Menu and Error LogWater Temperature Lamps DisplayService Menu Access Conveyor Speed SwitchReady Lamp Wash LampItem and Details Setting Range Display Service Menu ChartBuzzer Temperature DisplayError Codes Low Water Temperature Lock Function Continuous Wash ModeOperation Time Display Special ModesOFF Switch Open/Closed Display Mode III. Service DiagnosisDiagnostic Procedure Page Error Code Table Error CodesError Code Log Auto Fill Error A1 Error Code DetailsPage Booster Tank Auto Fill Error A2 Wash Tank Water Level Error A3 Page Page Wash Tank Thermistor Error H1, H2 Booster Tank Thermistor Error H3, H4 Eeprom Error H6 ROM/RAM Error H5Conveyor Overload or Table Limit Error 1 L1 Conveyor Overload or Table Limit Error 2 L2 Booster Tank Error b1 Booster Tank Water Level Safety Error b2 Unit Will Not Start Service Flow ChartsSee III.B. Error Codes Replace Dishes Not Clean Page Inadequate Rinse Dishwasher will not start wash/rinse cycle Dishwasher Will Not Start Wash/Rinse CycleWash Tank Water Boils No or Inadequate Detergent/Rinse Aid SupplyWash Tank Water Not Draining Float Switch Cleaning Float Switch Check and CleaningFloat Switch Check Thermistor Check Removal of Panels IV. Removal and Replacement of ComponentsRemoval and Replacement of Wash Pump Motors Removal and Replacement of Rinse Pump Motor Rinse Pump Motor Page Removal and Replacement of Gear Motor Removal and Replacement of Conveyor Removal and Replacement of Crankshaft Removal and Replacement of Thermistor Removal and Replacement of Control BoxControl Board Removal and Replacement of Control Board or Operation BoardOperation Board Removal and Replacement of Heater Removal and Replacement of Float Switch Removal and Replacement of Thermostat Cleaning and Maintenance Instructions Daily Maintenance Wash the curtains Silverware Rack Rail Ring Install the curtain L in the wash compartment Monthly Inspection Weekly MaintenanceHeater ExteriorShutdown Descaling As RequiredService Panel Hook VI. Operating Instructions Long Storage, Relocation, Disposal, TransferVII. Technical Information Water Circuit Wiring Diagram
Related manuals
Manual 61 pages 38.47 Kb

JWE-2400CUA-R-25B, JWE-24000CUA-L-25B specifications

The Hoshizaki JWE-2400CUA-R-25B and JWE-24000CUA-L-25B are advanced ice machines designed to meet the diverse needs of commercial establishments requiring high volumes of ice. These state-of-the-art units combine innovative technology with energy efficiency, making them ideal for restaurants, hotels, bars, and other hospitality settings.

One of the main features of the JWE-2400CUA-R-25B is its high production capacity. This model can produce up to 2,400 pounds of ice in a 24-hour period, ensuring a continuous supply for busy operations. Similarly, the JWE-24000CUA-L-25B boasts an impressive production rate, accommodating even larger establishments. Both machines deliver crescent-shaped ice, which is favored for its rapid cooling properties and ease of use in beverages.

Energy efficiency is a highlight of both models. They are designed with environmentally friendly refrigerants, aligning with modern sustainability practices. These machines also incorporate advanced heat-exchange systems that maximize energy savings while maintaining optimal ice production. As a result, operators can enjoy significant reductions in energy costs without compromising on performance.

Durability and reliability are essential characteristics of the Hoshizaki JWE series. Constructed with high-quality materials, these units feature stainless steel exteriors that resist corrosion and wear, ensuring long-term operation in demanding environments. Additionally, the ice-making components are built to endure frequent use, allowing for consistent ice output over time.

The technology integrated into the JWE-2400CUA-R-25B and JWE-24000CUA-L-25B includes user-friendly digital controls that simplify operation and monitoring. These controls help operators track production levels, ice thickness, and machine status, allowing for proactive maintenance and reducing downtime. Furthermore, routine cleaning and maintenance are made straightforward, contributing to enhanced hygiene and overall ice quality.

In conclusion, the Hoshizaki JWE-2400CUA-R-25B and JWE-24000CUA-L-25B ice machines present a perfect blend of high capacity, energy efficiency, and durability. Their advanced features and technologies make them a reliable choice for any business requiring dependable ice production. With their user-friendly controls and robust design, these machines stand out as top contenders in the commercial ice maker market.